Nuvo NV-E6DMS-DC, NV-E6DXS-DC manual RESPONSE Same response as for #IRSETSR CR

Models: NV-E6DXS-DC NV-E6DMS-DC

1 29
Download 29 pages 44.92 Kb
Page 24
Image 24
RESPONSE: Same response as for #IRSETSR<CR>

NOTE: the Main Unit ships with the carrier frequency DEFAULT setting of 38 KHz for all six sources.

*********************************************************************************

COMMAND: *IRSETDF<CR> Restores DEFAULT SOURCE IR carrier frequency settings (38 KHz for all six sources).

RESPONSE: Same response as for #IRSETSR<CR>

*********************************************************************************

COMMAND: *SxIR56SET<CR> - sets SOURCE x to 56 KHz IR repeat carrier (x is 1 to 6).

RESPONSE: Same response as for #IRSETSR<CR>

*********************************************************************************

COMMAND: *SxIR38SET<CR> - sets SOURCE x to 38 KHz IR repeat carrier (x is 1 to 6).

RESPONSE: Same response as for #IRSETSR<CR>

*********************************************************************************

COMMAND/RESPONSE DESCRIPTIONS.

NOTE zone number field xx should ALWAYS include a lead zero (“0”) for zone numbers less than 10.

COMMAND: *ZxxCONSR<CR> - Connect STATUS REQUEST where xx is zone # from 1 to 12.

RESPONSE: #ZxxPWRppp,SRCs,GRPt,VOL-yy,Pzzz<CR>-ppp = “ON” (2 characters) or “OFF” (3 characters)

The remaining fields are not included in the response if ppp is “OFF”:

-s = SOURCE NUMBER 1 to 6

-q = 0 if SOURCE GROUP is ON 1if SOURCE GROUP is OFF

-yy = level below max in dB: -00 to -78 dB (include lead 0 for all single-digit values)

-yy = “MT” if in MUTE state

-yy = “XM” if external MUTE is being held active

-zzz = “MST” if this zone is PARTY MASTER -zzz = “SLV” if this zone is SLAVED to a

PARTY MASTER in another zone

-zzz = “OFF” if this zone is under LOCAL CONTROL only (either there is no party master, or this zone has been manually

overridden)

This response will also be issued in response to pressing the ON/OFF, VOLUME, or SOURCE keys on a KEYPAD. NOTE the response will be issued if a SOURCE key is pressed on a zone that is powered OFF even though the key press has no effect on the system. It will be output at every increment during a volume ramp initiated by HOLDING a VOLUME UP or VOLUME DOWN key on a keypad. It will also be issued at every increment of a volume ramp commanded by the *ZxxVOL+<CR> and *ZxxVOL-<CR>commands (see below).

The MUTE value will be asserted if a *ZxMTON<CR> command has been received, OR if the volume is run all the way to the lowest possible point (volume off). An active EXTERNAL

23

Page 24
Image 24
Nuvo NV-E6DMS-DC, NV-E6DXS-DC manual RESPONSE Same response as for #IRSETSR CR

FAQ

What is the default carrier frequency setting for all six sources?

The default carrier frequency setting for all six sources is 38 KHz.

How can I restore the default IR carrier frequency settings for all six sources?

You can restore the default IR carrier frequency settings for all six sources by using the *IRSETDF command.

What is the response to the *ZxxCONSR command?

The response to the *ZxxCONSR command includes the power status, source number, source group status, volume level, mute state, party master status, and local control status for the specified zone.