COMMAND: *ZxxMTOFF<CR> zone xx MUTE OFF (returns zone output to currently connected source at previous volume setting).

RESPONSE: Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND: *ZxxBASSyyy<CR> zone xx BASS EQ with yyy = EQ level, dB, 12 to +0 (flat) to +12 in 2 dB increments.

USE LEAD “0” IN TENS PLACE FOR VALUE LESS THAN 10. RESPONSE: Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will override the non-volatile BASS setting (set from keypad) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxTREByyy<CR> zone xx TREBLE EQ with yyy = EQ level, dB, 12 to +0 (flat) to +12 in 2 dB increments.

USE LEAD “0” IN TENS PLACE FOR VALUE LESS THAN 10. RESPONSE: Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will override the non-volatile TREBLE setting (set from keypad) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxGRPON<CR> zone xx SOURCE GROUP ON.

RESPONSE: Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will override the non-volatile GROUP setting (set from keypad) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxGRPOFF<CR> zone xx SOURCE GROUP OFF.

RESPONSE: Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the will override the non-volatile GROUP setting (set from keypad) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxVRSTON<CR> zone xx VOLUME RESET ON.

RESPONSE: Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxVRSTOFF<CR> zone xx VOLUME RESET OFF.

RESPONSE: Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxLKON<CR> zone xx KEYPAD LOCK ON This will INHIBIT ANY keypad control input on the zone. This is the same as activating the Parental lock control at a keypad by holding down a SOURCE key for three seconds).

RESPONSE: #ZxxLKON<CR>6

26

Page 27
Image 27
Nuvo NV-E6DXS-DC, NV-E6DMS-DC manual Response Same response as for *ZxxSETSRCR