Alarm message list/Troubleshooting

Message

Meaning

Explanation

Action

[Can’t make the

 

The file for management

Connect the recorder to

system file. Connect

The management file

cannot be created due

a computer and delete

to PC and delete

cannot be created.

to a shortage of capacity

any unnecessary files.

unnecessary file]

 

for remaining memory.

 

 

[Cannot play this file]

File which cannot be

 

Please confirm the file

Incompatible format.

that can be played on

played.

 

 

this recorder (P.34).

 

 

 

 

 

 

 

[This file can't be

 

Attempting to split a file

 

File which cannot be

besides the MP3 or PCM

Please select another file.

divided]

split.

files recorded in this

 

 

 

recorder.

 

 

 

 

 

Troubleshooting

Symptom

Probable cause

Action

 

The batteries are not loaded properly.

Verify that the batteries’ polarities =

 

and -are correct (P.10).

 

 

Nothing appears on

 

Charge the battery (For WS-710M,

Battery power is getting low.

WS-700M only) or replace with new

the display

 

battery (P.10, P.12).

 

 

 

 

 

 

The power is off.

Turn the power on (P.15).

 

 

 

 

 

Charge the battery (For WS-710M,

 

Battery power is getting low.

WS-700M only) or replace with new

 

 

battery (P.10, P.12).

Won’t start

The power is off.

Turn the power on (P.15).

 

 

 

 

 

The recorder is in HOLD mode.

Release the recorder from HOLD

 

(P.16).

 

 

 

Low remaining memory.

Erase unnecessary files (P.39).

Unable to record

 

 

The maximum number of files has

Change to the another folder

 

 

been reached.

(P.22 to P.24).

 

The earphone is connected.

Unplug the earphones to use the

 

internal speaker.

 

 

No playback tone

[Speaker] is set to [Off].

To play back using the built-in speaker,

heard

set [Speaker] to [On] (P.47, P.57).

 

 

The volume level is set to [00].

Adjust the volume level (P.31).

 

 

 

7

list/Troubleshooting message Alarm

EN