Command Set 4-12
Command: #1RR
Response: *1RRFF
Read Setup (RS or RSU)
The read setup command reads back the setup information stored in the
A2400’s EEPROM with the SetUp (SU) command. The response to the RS
or RSU command is four bytes of information formatted as eight hex
characters.
The response contains the module’s channel address, baud rate and
otherparameters. Refer to the SetUp (SU) command for a list of parameters
in the setup message.
When reading the setup message with a checksum, be sure not to confuse
the checksum with the setup information.
Command: $1RS
Response: *31050000
Command: $1RSU
Response: *31050000
Command: #1RS
Response: *1RS3105000089
Command: #1RSU
Response: *1RSU31050000DE
Read Short Prompt (RSP)
The Read Short Prompt command reads back the extended addressing
short form command prompt stored in the module’s nonvolatile memory with
the Short Prompt (SP) command. The response to the RSP command is a
two character hex value of the ASCII short form prompt character.
Command: $1RSP (7B = { = Factory Setup)
Response: *7B
Command: #1RSP
Response: *1RSP7BC9