4.3.1 Main Control Window Pull-Down Operations
Below are the operations that are available in the Pull-Down Menus of the DAQ
Central Main Control Window.
Figure 4-5. File Menu
Open Configuration Opens Device Configuration settings from a saved file
Save Configuration As Saves current Device Configuration settings to a new file name
These settings files contain all of the data that is found in the Device
Configuration window.
Figure 4-6. Device Menu
Detect Devices Detects available OM-DAQ-USB-2401 devices which are currently
connected to the computer through the USB.
Configuration Same function as Configuration button .Accesses the device
Configuration window to configure ‘Channels’ settings, ‘Triggers’
settings, and ‘Data’ settings.
Start Acquisition Same function as Start button .. Initiates data acquisition for
the highlighted device. Even if a Start Trigger is set, this must be
selected to Arm the device.
Stop Acquisition Same function as Stop button . Stops data acquisition for the
highlighted device. If a Stop Trigger is set, this will cancel the trigger.