2.9Analog Input Signal Connection

FIG 1: Connecting analog input configuration

OME-A-8111

A/D CH0

A/D CHn

Es

AGND

Signal Shielding

zSignal shielding connections are shown in Fig1.

zUse single-point connection to frame ground (not AGND or DGND)

Vin

OME-A-8111

AGND

DGND

Frame Ground