Omega Engineering OME-A8111 manual I/O Register Address, Address Read Write

Models: OME-A8111

1 34
Download 34 pages 17.11 Kb
Page 13
Image 13

2.4I/O Register Address

The OME-A-8111 occupies 16 consecutive PC I/O addresses. The following table lists the registers and their locations.

Address

Read

Write

Base+0

8254 Counter 0

8254

Counter 0

Base+1

8254 Counter 1

8254

Counter 1

Base+2

8254 Counter 2

8254

Counter 2

Base+3

Reserved

8254

Counter Control

Base+4

A/D Low Byte

D/A Channel 0 Low Byte

Base+5

A/D High Byte

D/A Channel 0 High Byte

Base+6

DI Low Byte

Reserved

Base+7

DI High Byte

Reserved

Base+8

Reserved

A/D Clear Interrupt Request

Base+9

Reserved

A/D Gain Control

Base+A

Reserved

A/D Multiplexer Control

Base+B

Reserved

A/D Mode Control

Base+C

Reserved

A/D Software Trigger Control

Base+D

Reserved

DO Low Byte

Base+E

Reserved

DO High Byte

Base+F

Reserved

Reserved

OME-A-8111 Hardware Manual (ver.1.1, Jul/2003)