SW2 Setting

SW2 Setting

O N

O F F 1

2

S W 2 D e f a u l t S e t t i n g

S t a r t B i t s : 1

D a t a B i t s : 8

S t o p B i t s : 1

P a r i t y : N o n e

1

2

Start Bit

Data Bits

Stop Bit

Parity

Packet Data Bits

OFF

OFF

1

7

1

0

9

 

 

1

6

1

1

 

OFF

ON

1

8

1

0

10

 

 

1

7

1

1

 

ON

OFF

1

9

1

0

11

 

 

1

8

1

1

 

ON

ON

1

10

1

0

12

 

 

1

9

1

1

 

2.3.Installation

Software Utility

Software is not necessary for this module.

Equipments for Installation

A host computer with RS-232 port

RS-232 cable (DB-9 female)

DC Power supply (+10V~+30V) (NDP-243u is recommended)

Wires (shielded and grounded is recommended)

Installation Procedure

1.Make sure the host computer is power off.

2.Use RS-232 cable to connect OMR -6520 with host computer.

3.Wire the power supply to OMR. Note that the power supply should meet the specification.

4.Wire other OMRs.

Application Wiring

The Figure 2 -1 shows the application wiring of OMR -6520.

Host

Computer

OMR-6520

RS-232/RS-485 Converter

OMR module

RS-232

Local Power Supply +10 V to +30 V

+Vs GND

DATA +

DATA -

+Vs GND

+DATA - DATA

+Vs GND

OMR-6520 2-7