2Using the Handheld Infrared Thermometer
String | Description |
|
|
E:95; | Emissivity is 0.95 |
|
|
MAX:78; | Maximum temperature is 78 |
|
|
MIN:65; | Minimum temperature is 65 |
|
|
DIF:13; | Differential temperature is 13 |
|
|
AVG:72; | Average temperature is 72 |
|
|
DIS:1144; | Distance is 11.44 feet (always in feet) |
|
|
HAL:900; | High alarm set point (HAL) is 900 |
|
|
TC:74; | Thermocouple temperature is 74 |
|
|
TEF:0; | Thermocouple temp |
|
|
LAL:20; | Low alarm set point (LAL) is 20 |
|
|
AMB:125; | Target ambient temperature is 125 |
|
|
PRN:5; | Data transmission interval is every 5 seconds |
|
|
PRNF:1; | PRN Flag (0: PRN disabled, No data transmission, 1: PRN enabled, |
| Data communication active) |
|
|
IR:73; | Current Infrared temperature is 73 |
|
|
CF:0; | Temperature engineering unit (CF:1 in Degree C, CF:0 in Degree F) |
|
|
FF:1; | Temperature engineering unit (FF:1 in Degree F, FF:0 in Degree C) |
|
|
LF:0 | Temperature over range flag |
| xxxx0xxx : In Range, Top |
| xxxxIxxx : Out of Range, Top |
| xxxxx0xx : In Range, Bottom |
| xxxxxIxx : Out of Range, Bottom |
|
|
End | End of data string |
|
|