3.4.1 Serial Port
(Refer to Fig. 14 on previous page).
Serial Parameter
Baud rate: for setting the baud rate of the WiSER2400’s serial port. Supported values: 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, and 115200 bps.
Default value: 9600 bps
Parity Bit: for setting the
Data Bit: for setting the number of bits in the data section. Supported valued: 7 and 8.
Stop Bit: | supported value: 1. |
Flow Control: for setting local flow control option for the serial connection. Supported modes: None, XON/XOFF and Hardware flow control.
Serial Interface
The WiSER2400.IP supports
The WiSER2400.Plus supports
Data Packetizing
Start Frame Byte(s): This value specifies a special character or characters that signals the start of a
Default value: none
End Frame Byte: This value specifies the character that signals the end of a
Default value: 0x0D = Carriage Return
If the user specifies ‘None’ (or leaves the field blank), this will signify that there is no End Frame Byte and data will be sent immediately once the WiSER2400 receives the next Start Frame Byte.
Max Bytes/Pkt: This value specifies the maximum number of bytes the WiSER2400 will hold before they are sent off.
Range: 1 to 200 bytes.
Default value: 200 bytes
Serial Mode
Data Only Mode: When this mode is activated, the WiSER2400 serial port would accept only communication data traffic and ignore the configuration command. This mode will stop the communication between the administrative software and the WiSER2400. To re- gain the access to the WiSER2400 for administration, refer to the Troubleshooting Section for recovery instructions.
Default value: Data Only Mode
Data and Command Mode:
In this mode, the WiSER2400 serial port accepts both communication data traffic and the administration commands.
WiSER 2400 Technical Manual | Version 2.16 | Copyright | Page 23 of 32 |