OTC Wireless WiSER2400.IP, WiSER2400.Plus Serial-IP-Proxy, WiSER2400 administration software

Models: WiSER2400.Plus WiSER2400.IP

1 32
Download 32 pages 6.93 Kb
Page 24
Image 24
3.4.2 Serial-IP-Proxy

3.4.2 Serial-IP-Proxy

MAC Address: the MAC address of the WiSER2400. This field is not modifiable.

DHCP Enable: Allows the WiSER2400 to obtain IP address from a DHCP server.

IP Address: The IP address of the WiSER2400, user configurable.

Listen Port: The port number used by the WiSER2400 to communicate. This is the source port number in the TCP/UDP packets sent from this WiSER2400. Default value: 8002.

Subnet Mask: For configuring the subnet mask settings.

Gateway: For specifying the IP address of the Gateway.

Protocol

TCP (Client): For setting the WiSER2400 as a TCP Client.

TCP (Server): For setting the WiSER2400 as a TCP Server.

UDP:

For setting up the WiSER2400 to run UDP protocol:

Receive Broadcast Packet: Optional operation mode to enable the WiSER2400 to receive UDP broadcast packets.

Send Serial Data Broadcast: Optional operation mode to enable the data received from the WiSER2400 serial port to be transmitted wirelessly as UDP broadcast packets.

Note: The WiSER2400 can only operate in either UDP mode or TCP mode, but not in both modes simultaneously.

Fig. 15 WiSER2400 administration software

Configuration/Serial-IP-Proxy panel

WiSER 2400 Technical Manual

Version 2.16

Copyright  2001-2005, OTC Wireless, Inc. All Rights Reserved

Page 24 of 32

Page 24
Image 24
OTC Wireless WiSER2400.IP, WiSER2400.Plus WiSER2400 administration software, Configuration/Serial-IP-Proxy panel