POST Error Messages List

If you cannot run the diagnostics program tests but did receive a POST error message, use “POST Error Messages List” to diagnose system problems. If you did not receive any error message, look for a description of your error symptoms in “Error Symptoms List” on page 66.

NOTE: When you have deemed it necessary to replace an FRU, and have done so, you must run a total system check to ensure that no other activity has been affected by the change. This system check can be done through the diagnostics program.

NOTE: Check all power supply voltages, switch, and jumper settings before you replace the main board. Also check the power supply voltages if you have a “system no-power” condition.

If you are unable to correct the problem by using the “BIOS Messages List” table and “Error Symptoms List” table, go to “Undetermined Problems”.

To diagnose a problem, first find the BIOS error messages in the left column. If directed to a check procedure, replace the FRU indicated in the check procedure. If no check procedure is indicated, the first Action/FRU listed in right column is the most likely cause.

BIOS Messages

Action/FRU

BIOS ROM

The checksum of the BIOS code in the BIOS chip is incorrect, indicating the BIOS

checksum error -

code may have become corrupt. Contact your system dealer to replace the BIOS.

System halted

 

 

 

CMOS Battery

The CMOS battery is no longer functional. Contact your system dealer for a

Failed

replacement the BIOS.

 

 

CMOS Checksum

Checksum of CMOS is incorrect, so the system loads the default equipment

Error- defaults

configuration. A checksum error may indicate that CMOS has become corrupt. A

loaded

weak battery may have caused this error. Check the battery and replace if

 

necessary.

CPU at nnnn

Displays the running speed of CPU.

 

 

Display switch is set

The display switch on the motherboard can be set to either monochrome or color.

incorrectly

This message indicates the switch is set to a different setting than indicated

 

in Setup. Determine which setting is correct, and

 

then either turn off the system and change the jumper, or enter Setup and

 

change the Video selection.

Press ESC to skip

The user may press Esc to skip the full memory test.

memory test

 

 

 

HARD DISK

Some hard drives require extra time to initialize.

initializing - Please

 

wait a moment

Cannot find or initialize the hard drive controller or the drive. Make sure the controller

HARD DISK

INSTALL FAILURE

is installed correctly. If no hard drives are installed, be sure the Hard Drive Selection

 

in Setup is set to NONE.

 

 

Hard disk(s)

The system may run specific disk diagnostic

diagnosis fail

routines. This message appears if one or more hard disks return an error when the

 

diagnostics run.

 

 