If trouble is detected immediately after the power is turned on or during operation, the display window (LCD), WARNING lamp, lamps inside the viewfinder, and warning tones from the speaker and earphone inform the operator of trouble.
| Display window (LCD) | Lamps |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Remain- | Remain- |
|
| Warning | Warning | VTR (section) |
|
Item | Warning | Warning | ing | WARN- | REC | Countermeasures | ||||
display | battery | ing tape | ING | tone | contents | operation |
| |||
| display | length | lamp |
|
|
|
| |||
| status | level | lamp |
|
|
|
| |||
|
| display |
|
|
|
|
| |||
|
|
| display |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Head clogging is |
|
|
|
|
|
|
|
|
|
| detected and a |
|
|
|
|
|
|
|
|
|
| warning tone |
|
|
|
|
|
|
|
|
|
| emitted. Images | Clean the heads. |
|
|
|
|
|
|
| Emitted |
| may not be | If images still |
|
|
|
|
| Flashes | Flashes | Video head | recorded properly. | cannot be | |
|
|
|
|
| 4 times | |||||
|
| Flashes |
|
| 4 times | 4 times | clogging, | RF flashing status | recorded properly | |
RF | RF |
|
| per | ||||||
F1) |
|
| per | per | recording | can be held until | after the heads | |||
|
|
|
| second | ||||||
|
|
|
|
| second | second | system trouble | REC/PAUSE | are cleaned, | |
|
|
|
|
| F1) | |||||
|
|
|
|
|
|
|
|
| mode is activated, | consult your |
|
|
|
|
|
|
|
|
| and it goes off | dealer. |
|
|
|
|
|
|
|
|
| when REC/ |
|
|
|
|
|
|
|
|
|
| PAUSE mode is |
|
|
|
|
|
|
|
|
|
| released. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Turn off the power |
|
|
|
|
|
|
|
|
|
| and consult your |
|
|
|
|
| Flashes | Flashes | Emitted |
| Recording | dealer. (Lamps |
|
|
|
|
|
| continues, but | may flash briefly | |||
|
|
|
|
| 4 times | 4 times | 4 times | The servo is | ||
SERVO | SERVO | Lighted |
|
| images may not | and then go off | ||||
|
| per | per | per | out of order. | |||||
|
|
|
|
| be recorded | when tape running | ||||
|
|
|
|
| second | second | second |
| ||
|
|
|
|
|
| properly. | starts, but this | |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| does not indicate |
|
|
|
|
|
|
|
|
|
| trouble.) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Emitted |
| Recording | If tape running |
|
|
|
|
|
|
| 4 times |
| stops and the | |
|
|
|
|
|
|
|
| continues, but | ||
|
|
|
|
|
|
| per |
| HUMID display | |
|
|
|
|
|
| Flashes |
| stops if tape | ||
|
|
|
|
|
| second |
| does not go off | ||
|
|
|
|
|
| 4 times |
| sticking occurs. | ||
HUMID | HUMID | Lighted |
|
| Lighted | F1) | Condensation | even when the | ||
|
|
|
|
|
| per |
|
| Playback, fast | power is turned off |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| second | Continu- |
| forward and | |
|
|
|
|
|
|
| and then on again, | |||
|
|
|
|
|
|
| ous |
| rewind operation | |
|
|
|
|
|
|
|
| wait until the | ||
|
|
|
|
|
|
| tone F2) |
| stops. | |
|
|
|
|
|
|
|
| display goes off. | ||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| An error code | Check the error |
|
|
|
|
|
|
|
|
| appears in the | |
|
|
|
|
| Flashes | Flashes |
|
| code in the display | |
|
|
|
|
| Continu- |
| time code display | |||
SLACK | SLACK | Flashes |
|
| 4 times | 4 times | Tape | window (see | ||
|
| per | per | ous | trouble | position of the | page 149) and | |||
|
|
|
|
| tone | display window | ||||
|
|
|
|
| second | second |
| consult your | ||
|
|
|
|
|
|
| (LCD) and the | |||
|
|
|
|
|
|
|
|
| dealer. | |
|
|
|
|
|
|
|
|
| VTR stops. | |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
F1) During recording |
|
|
|
|
|
|
|
|
| |
F2) During playback, fast forward or rewind |
|
|
|
|
|
|
|
Note{
If a cleaning tape is not available to deal with video head clogging, etc., first establish the STOP mode and then press the STOP button again while the RESET button on the side panel is kept depressed. While these buttons are held down, the cleaning roller will clean the heads for a maximum of 10 seconds.
– 147 –