Inspections Before Shooting
Inspecting the Iris and Zoom Functions
1
2
3
4
5
6 Return the iris to automatic adjustment mode and change the GAIN switch setting toL, M and H to check the following items.
ÁThe iris is adjusted with respect to subjects with the same brightness in accordance with the switch setting.
ÁThe gain value display on the viewfinder screen changes in accordance with the switch setting.
7 When a lens with an extender is mounted, set the extender to the used position to check that the extender functions properly.
Perform “(1) Tape Running Inspections” to “(4) Earphone and Speaker Inspections” below consecutively.
Inspecting the VTR Section
(1)Tape Running Inspections
1Set the VTR SAVE/STBY switch to SAVE and check that the VTR SAVE lamp inside the viewfinder lights.
2Set the VTR SAVE/STBY switch to STBY and check that the VTR SAVE lamp goes off.
3Set the
4Set the DISPLAY switch to CTL.
5Press the unit’s VTR START button and check the following items. ÁThe tape reels turn.
ÁThe counter display number changes.
ÁThe REC lamp inside the viewfinder lights.
ÁThe RF and SERVO lamps in the display window do not light.
6Press the unit’s VTR START button again. Check that the tape stops and the REC lamp inside the viewfinder goes off.
7Check the same operations as in steps 5 and 6 using the VTR button of the lens.
8Press the RESET button and check that the counter display number changes to “00:00:00:00”.
9Set the LIGHT switch to ON and check that the display window is illuminated.
10 Press the REW button to rewind the tape for a few moments, and then press the PLAY/ PAUSE button. Check that the recording, playback and rewind operations are performed properly.
11 Press the FF button and check that fast forward operation is performed properly.
– 153 –