Chapter 7 Menu description tables (continued)
| Item | Variable | Remarks | |||
| range | |||||
|
|
|
|
|
| |
|
|
|
|
|
|
|
R GAIN AWB PRE | For setting the Rch gain when the WHITE | |||||
|
|
|
|
| : | BAL switch is in the PRST position. |
|
|
|
|
| +000 | |
|
|
|
|
| O If the remote control unit is connected, | |
|
|
|
|
| : | |
|
|
|
|
| +200 | settings made from the menu are |
|
|
|
|
|
| disabled. (The set value is displayed.) |
S | C | U | F | R |
|
|
|
|
|
|
|
|
|
B GAIN AWB PRE | For setting the Bch gain when the WHITE | |||||
|
|
|
|
| : | BAL switch is in the PRST position. |
|
|
|
|
| +000 | |
|
|
|
|
| O If the remote control unit is connected, | |
|
|
|
|
| : | |
|
|
|
|
| +200 | settings made from the menu are |
|
|
|
|
|
| disabled. (The set value is displayed.) |
S | C | U | F | R |
|
|
|
|
|
|
|
|
|
R GAIN AWB A | For setting the Rch gain when the WHITE | |||||
|
|
|
|
| : | BAL switch is in the A position. |
|
|
|
|
| +000 | |
|
|
|
|
| O If the remote control unit is connected, | |
|
|
|
|
| : | |
|
|
|
|
| +200 | settings made from the menu are |
|
|
|
|
|
| disabled. (The set value is displayed.) |
S | C | U | F | R |
|
|
|
|
|
|
|
|
|
B GAIN AWB A | For setting the Bch gain when the WHITE | |||||
|
|
|
|
| : | BAL switch is in the A position. |
|
|
|
|
| +000 | |
|
|
|
|
| O If the remote control unit is connected, | |
|
|
|
|
| : | |
|
|
|
|
| +200 | settings made from the menu are |
|
|
|
|
|
| disabled. (The set value is displayed.) |
S | C | U | F | R |
|
|
R GAIN AWB B | For setting the Rch gain when the WHITE | |||||
|
|
|
|
| : | BAL switch is in the B position. |
|
|
|
|
| +000 | |
|
|
|
|
| O If the remote control unit is connected, | |
|
|
|
|
| : | |
|
|
|
|
| +200 | settings made from the menu are |
|
|
|
|
|
| disabled. (The set value is displayed.) |
S | C | U | F | R |
|
|
|
|
|
|
|
|
|
B GAIN AWB B | For setting the Bch gain when the WHITE | |||||
|
|
|
|
| : | BAL switch is in the B position. |
|
|
|
|
| +000 | |
|
|
|
|
| O If the remote control unit is connected, | |
|
|
|
|
| : | |
|
|
|
|
| +200 | settings made from the menu are |
|
|
|
|
|
| disabled. (The set value is displayed.) |
S | C | U | F | R |
|
|
|
|
|
|
|
|
|
AWB A GAIN | ON | For setting the values of the Rch gain and | ||||
OFFSET | OFF | the Bch gain when the auto white balance is | ||||
|
|
|
|
|
| executed as the WHITE BAL switch is in the |
|
|
|
|
|
| A position. |
|
|
|
|
|
| ON: To retain the values set in the items of |
|
|
|
|
|
| R GAIN AWB A and B GAIN AWB A |
|
|
|
|
|
| OFF: The values of the Rch gain and the |
S | C | U | F | R |
| Bch gain is set to “0”. |
|
|
|
|
|
|
|
AWB B GAIN | ON | For setting the values of the Rch gain and | ||||
OFFSET | OFF | the Bch gain when the auto white balance is | ||||
|
|
|
|
|
| executed as the WHITE BAL switch is in the |
|
|
|
|
|
| B position. |
|
|
|
|
|
| ON: To retain the values set in the items of |
|
|
|
|
|
| R GAIN AWB B and B GAIN AWB B |
|
|
|
|
|
| OFF: The values of the Rch gain and the |
S | C | U | F | R |
| Bch gain is set to “0”. |
| Item |
| Variable | Remarks |
|
| |||
|
| range |
| ||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
MASTER PED |
| For setting the level of the master pedestal. |
|
| |||||
|
|
|
|
|
| : | O If the remote control unit is connected, |
|
|
|
|
|
|
|
| +015 |
| ||
|
|
|
|
|
| settings made from the menu are |
|
| |
|
|
|
|
|
| : |
| ||
S | U F | R | +200 | disabled. (The set value is displayed.) |
| ||||
|
|
|
| ||||||
|
|
|
|
|
|
|
| ||
R PEDESTAL |
| For setting the pedestal level of the Rch. |
|
| |||||
|
|
|
|
|
| : | O If the remote control unit is connected, |
|
|
|
|
|
|
|
| +000 |
| ||
|
|
|
|
|
| settings made from the menu are |
|
| |
|
|
|
|
|
| : |
| ||
|
|
|
|
|
| +100 | disabled. (The set value is displayed.) |
| |
S | C | U | F | R |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
G PEDESTAL |
| For setting the pedestal level of the Gch. |
|
| |||||
|
|
|
|
|
| : | O If the remote control unit is connected, |
|
|
|
|
|
|
|
| +000 |
| ||
|
|
|
|
|
| settings made from the menu are |
|
| |
|
|
|
|
|
| : |
| ||
|
|
|
|
|
| +100 | disabled. (The set value is displayed.) |
| |
S | C | U | F | R |
|
|
| 7 | |
|
|
|
|
|
|
|
| ||
B PEDESTAL |
| For setting the pedestal level of the Bch. |
| ||||||
|
|
|
|
|
| : | O If the remote control unit is connected, |
| |
|
|
|
|
|
| +000 |
| ||
|
|
|
|
|
| settings made from the menu are |
|
| |
|
|
|
|
|
| : |
|
| |
|
|
|
|
|
| ||||
|
|
|
|
|
| +100 | disabled. (The set value is displayed.) |
| |
S | C | U | F | R |
|
|
|
| |
|
|
|
|
|
|
|
| ||
PEDESTAL |
| ON | For setting the pedestal levels of the Rch, |
|
| ||||
OFFSET |
|
|
| OFF | the Gch and the Bch when the black balance |
| |||
|
|
|
|
|
|
| is adjusted. |
| |
|
|
|
|
|
|
| ON: To retain the values set in the |
| |
|
|
|
|
|
|
| respective items of R PEDESTAL, G |
| |
|
|
|
|
|
|
| PEDESTAL, and B PEDESTAL |
| |
|
|
|
|
|
|
| OFF: The pedestal levels of the Rch, the |
| |
S | C | U | F | R |
| Gch and the Bch are set to”0”. |
|
| |
|
|
|
|
|
|
|
|
|
|
R FLARE |
| For adjusting the flare level of the Rch. |
|
| |||||
|
|
|
|
|
| : | Adjustment values in this item are added to |
|
|
|
|
|
|
|
| +000 |
| ||
|
|
|
|
|
| the flare adjustment value that is adjusted on |
|
| |
|
|
|
|
|
| : |
| ||
|
|
|
|
|
| +100 |
| ||
|
|
|
|
|
|
| O If the remote control unit is connected, |
| |
|
|
|
|
|
|
| settings made from the menu are |
| |
S | C | U | F | R |
| disabled. (The set value is displayed.) |
|
| |
|
|
|
|
|
|
|
| ||
G FLARE |
| For adjusting the flare level of the Gch. |
|
| |||||
|
|
|
|
|
| : | Adjustment values in this item are added to |
|
|
|
|
|
|
|
| +000 |
| ||
|
|
|
|
|
| the flare adjustment value that is adjusted on |
|
| |
|
|
|
|
|
| : |
| ||
|
|
|
|
|
| +100 |
| ||
|
|
|
|
|
|
| O If the remote control unit is connected, |
| |
|
|
|
|
|
|
| settings made from the menu are |
| |
S | C | U | F | R |
| disabled. (The set value is displayed.) |
|
| |
|
|
|
|
|
|
|
|
| |
B FLARE |
|
|
| For adjusting the flare level of the Bch. |
|
| |||
|
|
|
|
|
| : | Adjustment values in this item are added to |
|
|
|
|
|
|
|
| +000 |
| ||
|
|
|
|
|
| the flare adjustment value that is adjusted on |
|
| |
|
|
|
|
|
| : |
| ||
|
|
|
|
|
| +100 |
| ||
|
|
|
|
|
|
| O If the remote control unit is connected, |
| |
|
|
|
|
|
|
| settings made from the menu are |
| |
S | C | U | F | R |
| disabled. (The set value is displayed.) |
|
|
The underlining in the variable range column indicates the setting in the preset mode.
107