Chapter 4 Adjustments and settings for recording (continued)

4-10-3 How to use the user data

The setting data can be written in the user data area of the unit’s internal memory and data written in the memory can be read from this area.

Use of this data speeds up the process of reproducing suitable setup statuses.

Writing the setting data in the user area

1 Perform a menu operation to open the <INITIALIZE> screen.

2 Turn the JOG dial button to move the arrow (cursor) to the WRITE USER DATA item.

< INITIALIZE >

READ FACTORY DATA

#WRITE USER DATA

3 When the JOG dial button is pressed, the following message appears.

WRITE?

YES

#NO

4 Turn the JOG dial button to move the arrow (cursor) to YES, and press the JOG dial button.

The setting data is now written in the user data area of the unit’s internal memory.

5 Press the MENU button to exit the menu operations.

Loading the user data

1 Perform a menu operation to open the <SCENE> screen.

2 Turn the JOG dial button to move the arrow (cursor) to the READ USER DATA item.

<SCENE >

#READ USER DATA

SCENE SEL

:1

4

READ

 

WRITE

 

RESET

TITLE1 : ********

TITLE2 : ********

TITLE3 : ********

TITLE4 : ********

3 When the JOG dial button is pressed, the following message appears.

READ?

YES

#NO

4 Turn the JOG dial button to move the arrow (cursor) to YES, and press the JOG dial button.

The data written in the user data area of the unit’s internal memory is now read, and the setting is completed.

5 Press the MENU button to exit the menu operations.