Chapter 6 Maintenance and inspections (continued)

5.Inspection using external microphones

1Connect external microphones to the AUDIO IN CH1 and CH2 jacks.

2Set the AUDIO IN CH1 and CH2 switches to REAR.

3Set the LINE/MIC/+48V selector switch on the back panel to MIC or +48V in accordance with the external mic’s power supply type.

MIC : Internal power supply mic.

+48V : External power supply mic.

4Point the microphones at the sound source, and check that the changes in the audio levels displayed on the audio level meter of the display window and in the viewfinder reflect the changes in the strength of the sound.

This inspection can also be performed for each channel by connecting one of the microphones to each channel in turn.

6.Inspections relating to the time code and user bits

1Set the user bits as required.

For details on the setting procedure, refer to “4-5-1 Setting the user bits.”

2Set the time code.

For details on the setting procedure, refer to “4-5-3 Setting the time code.”

3Set the TCG switch to R-RUN.

4Press the REC START button.

Check that the figure on the counter display changes as the tape travels.

5Press the REC START button again.

Check that the tape stops and the figure shown on the counter display stops changing.

6Set the TCG switch to F-RUN.

Check that the figure on the counter display changes irrespective of the tape travel.

7Set the DISPLAY switch to UB.

Check that pressing the HOLD button advances the display value through the sequence VTCG > DATE > TIME > no display (time zone) > TCG.

6-1-4 Self-diagnosis function

Simplified checks can be undertaken on the unit’s system at such times when, for instance, a color video monitor is not available.

Perform menu operations to open the <SYSTEM CHECK> from the MAINTENANCE page. Check the camera output level setting under the COLOR CHECK item.

#< SYSTEM CHECK >

COLOR CHECK :OFF

Y: 0%

R: 0%

 

G:

0%

 

B:

0%