6. External interfaces

This unit comes with RS-422, GPI and tally connectors to serve as external interfaces.

6-1. RS-422 connector

This enables the unit to be controlled by an external device. Use it with the settings below.

Baud rate: 38400 bps

Parity: ODD

Stop bit: 1 bit

Pin assignment

� � � � �

� � � �

Pin No.

Signal name

Description of signal

1

FRAME GROUND

Frame ground

2

RXD –

Receive data (–)

3

TXD +

Send data (+)

4

GROUND

Ground

5

NC

Not used

6

GROUND

Ground

7

RXD +

Receive data (+)

8

TXD –

Send data (–)

9

FRAME GROUND

Frame ground

6-2. GPI connector

This enables auto take operations to be executed by an external device.

Auto transitions are executed at the fall of the GPI signals.

6-3. Tally connector

The tally connector comes with tally output, output enable, power supply or fan alarm output pins.

The output signals from the tally output pins are for lighting the tally lamps, and these outputs are open collector outputs.

 

 

� �

 

 

Pin assignment

 

 

 

 

 

 

 

 

 

 

 

Pin No.

Signal name

Input/output

 

 

Description of signal

1

IN1

Open collector output

 

Tally output of input video 1

2

IN2

Open collector output

 

Tally output of input video 2

3

IN3

Open collector output

 

Tally output of input video 3

4

IN4

Open collector output

 

Tally output of input video 4

5

IN5

Open collector output

 

Tally output of input video 5

6

IN6

Open collector output

 

Tally output of input video 6

7

ENABLE

Input

 

 

 

Enable signal of tally output

 

 

 

 

 

 

Open: Output; GND: no output

8

ALARM

Open collector output

 

Fan alarm or power supply alarm output

9

GROUND

GROUND

 

 

 

Ground