GElectronic Shutter Synchro Scan Setting [Synchro Scan: 50.24Hz to 15.63kHz]

This setting is possible only when Electronic Shutter setting is at S/Scan.

Horizontal bar noise can be reduced by synchro-scan adjustment in shooting workstation scenes, for example.

For luminance settings at each shutter speed and synchro-scan shutter speed, refer to the table below.

Shutter Speed

Synchro-scan

Required luminance ratio

 

 

 

 

OFF

 

1

 

 

 

 

1/120

120.2

Hz

2

 

 

 

 

1/250

250.0

Hz

4

 

 

 

 

1/500

492.2

Hz

8

 

 

 

 

1/1000

984.4

Hz

16

 

 

 

1/2000

1.969 kHz

32

 

 

 

1/4000

3.938 kHz

64

 

 

 

1/10000

7.875 kHz

160

 

 

 

 

HCCD Read Out Mode Setting [V Resolution: Normal, Fine]

Normal: Normal image. (CCD storage will be by field storage.)

Fine: Vertical resolution increases. (Vertical resolution is raised without increasing residual images by frame storage and Electronic shutter.)

Normal is recommended for general use because sensitivity will decrease at the Fine setting.

IPC Control Access Speed Setting [Baud Rate: 1200bps, 2400bps, 4800bps, 9600bps]

Select a communication speed in controlling the camera from the computer.

JComponent Output Setting [Signal Select: RGB, Y/Pr/Pb, Y/C]

This enables RGB, Y/Pr/Pb or Y/C to be selected as the component signals which are to be output from the I/F REMOTE connector.

KAspect Ratio Selection [Aspect Ratio: 16:9, 4:3] Aspect ratio can be selected from 16:9 or 4:3.

LFan Setting [Fan SW: OFF, Auto]

OFF: Select this setting to stop the fan when its operating sound is found to be bothersome in a studio or other such environment.

Auto: The temperature is detected automatically, and the fan starts operating when the temperature exceeds approx. 35°C.

Under normal circumstances, the “Auto” setting is used.

ENGLISH

- 38 (E) -

Page 39
Image 39
Panasonic AW-E860L manual CCD Read Out Mode Setting V Resolution Normal, Fine, 38 E