REMOTE Specifications (continued)

REMOTE Specifications (continued)

Priority of assigned functions

When both “MARKER1” and “MARKER2” are activated at the same time, “MARKER1” has priority. However, when the display aspect ratio is 4:3, the “MARKER1” aspect ratio is 16:9 and the “MARKER2” aspect ratio is 4:3, “MARKER2” is displayed. In this case, the “MARKER2” background is controlled.

When “MARKER BACK HALF” and “MARKER BACK BLACK” are activated at the same time, “MARKER BACK BLACK” has priority.

During GPI edge operation and two or more of “INPUT SEL. VIDEO”, “INPUT SEL. SDI1”, “INPUT SEL. SDI2”, “INPUT SEL. YPBPR/RGB” and “INPUT SEL. DVI-D” are simultaneously activated, priority goes to the last activated item. During level operation, priority is assigned in the following order: “INPUT SEL. VIDEO”, “INPUT SEL. SDI1”, “INPUT SEL. SDI2”, “INPUT SEL. YPBPR/RGB” and “INPUT SEL. DVI-D”.

When “GAMMA SEL. FILM” and “GAMMA SEL. STDIO/PST” are activated at the same time, “GAMMA SEL. FILM” has priority.

RS-232C terminal

The following diagram and the table on the lower right show RS-232C terminal pin arrangement and connections. For details on systems using RS-232C, be sure to consult your dealer.

 

PC Side

 

 

(Straight)

BT-LH2550 Side

 

Pin number

 

Signal

 

 

 

Pin number

Signal

 

 

 

 

 

 

 

 

 

 

1

 

N.C.

 

 

 

1

N.C.

 

 

 

 

 

 

 

 

 

 

2

 

RXD

 

 

 

2

TXD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

TXD

 

 

 

3

RXD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

DTR

 

 

 

4

DSR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

GND

 

 

 

5

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232C terminals (9P)

6

 

DSR

 

 

 

6

DTR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

RTS

 

 

 

7

CTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

CTS

 

 

 

8

RTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

N.C.

 

 

 

9

N.C.

 

 

 

 

 

 

 

 

 

RS-232C remote control method

Connectors and signals Connector: D-SUB 9-pin (female) Signal

Pin number

Signal

Description

1

N.C.

Not connected

 

 

 

 

2

TXD

Transmission data

 

 

 

 

3

RXD

Reception data

 

 

 

 

4

DSR

Connected inside

 

 

 

 

5

GND

Ground

 

 

 

 

6

DTR

Connected inside

 

 

 

 

7

CTS

Connected inside

 

 

 

 

8

RTS

Connected inside

 

 

 

 

9

N.C.

Not connected

 

 

 

 

Communication parameters

 

 

 

Signal level

 

RS-232C compliant

 

 

Synchro system

Asynchronous

 

 

 

Transfer rate

 

9600 bps

 

 

 

Parity

 

None

 

 

 

Data length

 

8 bit

 

 

 

Stop bit

 

1 bit

 

 

 

Flow control

 

None

 

 

 

 

Command format

STX (02h)

Command

:

Data

ETX (03h)

The command is the 3-character string starting with STX and ending with ETX.

Append any data after the colon (:) following the command, as required.

Response formats

1. Setting command response

 

STX (02h)

Command

 

ETX (03h)

2.

Query command response

 

 

 

 

 

 

STX (02h)

Data

 

ETX (03h)

 

 

 

 

 

3.

Error response

 

 

 

 

 

 

STX (02h)

Error code

 

ETX (03h)

 

 

 

 

 

 

Error codes

 

 

 

ER001: Invalid command

ER002: Parameter error