c. Patrol operation disable

To disable the Patrol Operation during unit start (default) with “OFF/ON” button, press “Patrol” button and hold for 5 seconds, then release.

To disable the Patrol Operation, press “Patrol” button and hold for 15 seconds, then release.

C. Control Content

a. Gas Sensor Control

First 2 minutes from Patrol function activates is stabilization time, during stabilization time, no air dirtiness level is monitored. The Air Dirtiness level is set to level 2.

After that, gas sensor starts to record the resistance value at fixed interval. Higher resistance value indicates cleaner air.

The air dirtiness level is monitored by comparing the current resistance value with maximum resistance value from time to time to get the Air Dirtiness Value.

There are 3 air dirtiness levels, based on the Air Dirtiness Value:

-Air Dirtiness level 0: Clean

-Air Dirtiness level 1: Moderate

-Air Dirtiness level 2: Contaminated

Dirtiness level sensitivity adjustment

It is possible to change the gas sensor sensitivity, where the Threshold value (G1 ~ G4) will be shifted accordingly:

1.Press and release “SET” buttton.

2.Press “Timer increment” / “Timer decrement” button to select sensitivity. (Low Standard (Default) High)

3.Confirm setting by pressing “Timer Set” button. LCD returned to original display after 2 seconds.

4.LCD returned to original display if remote control does not operate for 30 seconds.

b. e-ion Control

When dirtiness level is 1 or 2, e-ion operation starts.

If dirtiness level improves from level 2 to level 1, the unit carries out level change after 60 seconds.

When dirtiness level returns to level 0 continuously for 10 minutes or more, e-ion operation stops.

Dirtiness Level Shift

• For Auto Fan Speed, the fan speed increased based on dirtiness level:

c. Indoor Fan Control

During any operation mode combines with Patrol operation, fan speed follows respective operation mode.

During Patrol individual operation if e-ion starts, only Auto Fan Speed and no Powerful operation is allowed. Even if “Fan Speed” button is pressed, no signal is sent to air conditioner, and no change on LCD display.

During Patrol individual operation if e-ion stops, Indoor Fan stop operation.

d. Airflow direction (Horizontal, Vertical) Control

During any operation mode combines with Patrol operation, airflow direction follows respective operation mode.

During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if “Air Swing” button is pressed, no signal is sent to air conditioner, and no change on LCD display.

During Patrol individual operation if e-ion stops, Airflow direction louver closed.

43