17.2. Sensible Capacity Chart

O CS-CE7HKEW CU-CE7HKE

230V

 

 

 

 

 

Outdoor Temp. (θC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor wet

 

30

 

 

35

 

 

40

 

 

46

 

bulb temp.

 

 

 

 

 

 

 

 

 

 

 

 

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

 

 

 

 

 

 

 

 

 

 

 

 

 

17.0θC

2.03

1.54

0.43

1.90

1.48

0.46

1.77

1.42

0.50

1.61

1.35

0.53

 

 

 

 

 

 

 

 

 

 

 

 

 

19.0θC

 

 

 

2.05

 

0.47

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19.5θC

2.23

1.61

0.44

2.09

1.55

0.47

1.94

1.49

0.50

1.77

1.42

0.54

 

 

 

 

 

 

 

 

 

 

 

 

 

22.0θC

2.43

1.67

0.45

2.27

1.61

0.48

2.12

1.55

0.51

1.92

1.48

0.55

 

 

 

 

 

 

 

 

 

 

 

 

 

O CS-CE9HKEW CU-CE9HKE

230V

 

 

 

 

 

Outdoor Temp. (θC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor wet

 

30

 

 

35

 

 

40

 

 

46

 

bulb temp.

 

 

 

 

 

 

 

 

 

 

 

 

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

 

 

 

 

 

 

 

 

 

 

 

 

 

17.0θC

2.58

1.96

0.54

2.41

1.88

0.58

2.24

1.80

0.62

2.04

1.71

0.67

 

 

 

 

 

 

 

 

 

 

 

 

 

19.0θC

 

 

 

2.60

 

0.59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19.5θC

2.83

2.05

0.55

2.65

1.97

0.59

2.46

1.89

0.63

2.24

1.80

0.68

 

 

 

 

 

 

 

 

 

 

 

 

 

22.0θC

3.09

2.12

0.56

2.88

2.04

0.60

2.68

1.97

0.64

2.44

1.88

0.70

 

 

 

 

 

 

 

 

 

 

 

 

 

O CS-CE12HKEW CU-CE12HKE

230V

 

 

 

 

 

Outdoor Temp. (θC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor wet

 

30

 

 

35

 

 

40

 

 

46

 

bulb temp.

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

 

 

 

 

 

 

 

 

 

 

 

 

 

17.0θC

3.47

2.63

0.84

3.24

2.52

0.91

3.02

2.43

0.97

2.74

2.30

1.05

 

 

 

 

 

 

 

 

 

 

 

 

 

19.0θC

 

 

 

3.50

 

0.92

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19.5θC

3.81

2.76

0.86

3.56

2.65

0.92

3.31

2.55

0.99

3.01

2.43

1.07

 

 

 

 

 

 

 

 

 

 

 

 

 

22.0θC

4.15

2.86

0.87

3.88

2.75

0.94

3.61

2.65

1.01

3.28

2.53

1.08

 

 

 

 

 

 

 

 

 

 

 

 

 

TC - Total Cooling Capacity (kW)

SHC - Sensible Heat Capacity (kW)

IP - Input Power (kW)

Indoor 27θC/19θC

Outdoor 35θC/24θC

74