Remote Control Printed Circuit Board
| Jumper A | Jumper B | Remote Control No. |
|
|
|
|
| Short | Open | A (Default) |
|
|
|
|
| Open | Open | B |
|
|
|
|
| Short | Short | C |
|
|
|
|
| Open | Short | D |
|
|
|
|
•During Remote Control Number Switch Mode, press any button at remote control to transmit and store the transmission code to the EEPROM.
14.3. Remote Control Button
14.3.1. SET BUTTON
•To check current remote control transmission code
-Press for more than 10 seconds.
•To change the air quality sensor sensitivity
-Press and release with pointer.
-Press the Timer Decrement button to select sensitivity:
1.Low Sensitivity
2.Standard (Default)
3.Hi Sensitivity
-Confirm setting by pressing Timer Set button, a “Beep” sound will be heard. LCD returns to original display after 2 seconds.
-LCD returns to original display if remote control does not operate for 30 seconds.
14.3.2. CLOCK BUTTON
•To change the remote control’s time format
-Press for more than 5 seconds.
14.3.3. RESET (RC)
•To clear and restore the remote control setting to factory default
-Press once to clear the memory.
14.3.4. RESET (AC)
•To restore the unit’s setting to factory default
-Press once to restore the unit’s setting.
14.3.5. TIMER
•To change indoor unit indicator’s LED intensity
-Press continuously for 5 seconds.
14.3.6. TIMER
•To change remote control display from Degree Celsius (θC) to Degree Fahrenheit (θF).
-Press continuously for 10 seconds.