Table (b): Outdoor Air Temperature Shifting

Mode:

Outdoor Temperature, X (°C):

Temperature Shift (°C)

 

 

 

 

Manual Operation

Auto Operation

Cooling/Soft Dry

 

38

X

1.50

2.00

 

 

 

 

 

 

 

30

X

38

1.25

1.25

 

23

X

30

1.25

1.25

 

 

 

 

 

 

 

 

X

23

1.75

1.75

Heating

 

21

X

-2.25

-1.50

 

17

X

21

-1.75

-1.00

 

 

 

 

 

 

 

13

X

17

-0.75

0.00

 

9

X

13

0.25

0.25

 

 

 

 

 

 

 

5

X

9

1.25

1.00

 

1

X

5

0.75

1.00

 

-3 X 1

1.50

1.00

 

 

 

 

 

 

 

 

X

-3

1.50

1.00

Table (c): Powerful Mode Shifting

Mode:

Period, X (min):

Temperature Shift (°C)

Cooling

X

20

-2.0

 

X

20

0.0

 

 

 

 

Soft Dry

X

20

-1.0

 

X

20

0.0

 

 

 

 

Heating

X

20

+3.5

 

X

20

+3.25

Table (d): Quiet (Lo) Mode Shifting

Mode:

Period, X (min):

Temperature Shift (°C)

Cooling, Soft Dry

20 min

X

50 min

-3.0

 

50 min

X

110 min

-4.0

 

110 min

X

440 min

-5.0

Table (e): Fan Speed Shifting

Mode:

Fan Speed:

Temperature Shift (°C)

Cooling

Lo

-0.25

 

Me-, Me, Me+, Auto

0.00

 

 

 

 

Hi

+0.25

Soft Dry

All

+0.25

 

 

 

Heating

Lo

+1.50

 

Me-, Me, Me+, Auto

+0.75

 

Hi

+0.75

 

 

 

Table (f): Start-Up Shifting

Mode within 60 Minutes from Start-up:

Temperature Shift (°C)

Cooling/Soft Dry

-1.0

Heating

+2.0

16