How to use electronic circuit diagram
TIMER TABLE <INDOOR>
|
| Test mode |
Name | Time | (When test point |
|
| |
4 way valve abnormality | 4 min. | 24 sec. |
|
|
|
Outdoor air temp. for Hz No. decision | 30 min. | 0 sec. |
20 min. | 0 sec. | |
|
|
|
6 min. | 0 sec. | |
Thermo OFF delay | 3 min. | 0 sec. |
Low pressure control (gas leakage) compressor OFF time | 3 min. | 0 sec. |
|
|
|
Time delay safety control | 2 min. 58 sec. | 0 sec. |
| 20 sec. |
|
|
|
|
Odour timer status shift time | 90 sec. | 0 sec. |
| 20 sec. |
|
| 120 sec. |
|
|
|
|
Intake air temp. sampling time | 2 min. | 0 sec. |
Self diagnosis display time | 10 sec. | 0 sec. |
|
|
|
Auto mode judgement sampling time | 20 sec. | 0 sec. |
24 hours Real Timer | 1 hour | 1 min. |
Heating SSHi fan speed shift | 120 min. | 12 sec. |
|
|
|
Cooling SHi fan speed shift | 30 min. | 3 sec. |
Hot start forced completion | 4 min. | 0.4 sec. |
|
|
|
Auto mode judgement interval | 30 min. | 3 sec. |
After Hot start / Deice | 2 min. | 12 sec. |
TIMER TABLE <OUTDOOR>
|
| Test mode |
Name | Time | (When test point |
|
| |
DC PEAK | 30 sec. | 3 sec. |
|
|
|
| 120 min. | 24 sec. |
Deice detection | 80 min. | 16 sec. |
|
|
|
| 40 min. | 8 sec. |
| 40 min. | 8 sec. |
Hz lock time | 30 sec. | 0 sec. |
|
|
|
Outdoor fan delay operation control | 30 sec. | 3 sec. |
4 way valve delay operation control | 3 min. | 18 sec. |
|
|
|
97