Outdoor Temp. (°C)

 

 

 

 

 

Indoor wet

 

30

 

 

35

 

 

40

 

 

46

 

bulb temp.

 

 

 

 

 

 

 

 

 

 

 

 

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

17.0°C

5.26

3.99

1.51

4.91

3.82

1.63

4.57

3.67

1.74

4.16

3.49

1.88

 

 

 

 

 

 

 

 

 

 

 

 

 

19.0°C

 

 

 

5.30

 

1.65

 

 

 

 

 

 

19.5°C

5.77

4.17

1.54

5.40

4.01

1.66

5.02

3.86

1.77

4.56

3.67

1.91

22.0°C

6.29

4.33

1.57

5.88

4.16

1.69

5.47

4.01

1.80

4.97

3.83

1.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Temp. (°C)

 

 

 

 

 

Indoor wet

 

30

 

 

35

 

 

40

 

 

46

 

bulb temp.

 

 

 

 

 

 

 

 

 

 

 

 

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

TC

SHC

IP

17.0°C

6.25

4.74

2.02

5.84

4.54

2.18

5.43

4.37

2.33

4.94

4.15

2.51

 

 

 

 

 

 

 

 

 

 

 

 

 

19.0°C

 

 

 

6.30

 

2.21

 

 

 

 

 

 

19.5°C

6.86

4.96

2.06

6.41

4.77

2.22

5.97

4.59

2.37

5.42

4.37

2.56

22.0°C

7.48

5.14

2.10

6.99

4.95

2.26

6.50

4.77

2.42

5.91

4.55

2.61

 

 

 

 

 

 

 

 

 

 

 

 

 

TC - Total Cooling Capacity (kW)

Indoor 27°C/19°C

SHC - Sensible Heat Capacity (kW)

Outdoor 35°C/24°C

IP - Input Power (kW)

 

83