1.When the power supply is cut off during the operation of air conditioner, the compressor will
2.This type of control is not applicable during ON/OFF Timer setting.
8.1.15. Indication PanelLED | POWER MONITOR | POWER | QUIET | TIMER | POWERFUL | ION |
Color | Green | Green | Orange | Orange | Orange | Green |
Light ON | Compressor ON | Operation ON | Quiet Mode ON | Timer Setting ON | Powerful Mode ON | Ion Mode ON |
|
|
|
|
|
|
|
Light OFF | Compressor OFF | Operation OFF | Quiet Mode OFF | Timer Setting OFF | Powerful Mode OFF | Ion Mode OFF |
|
|
|
|
|
|
|
Note:
•If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation mode judgment, or delay ON timer sampling.
•If Timer LED is blinking, there is an abnormality operation occurs.
•If Ionizer, LED is blinking, there is an abnormality of Ionizer occurs.
Power Monitor LED Control Frequency
Lighting of 3 LED base on instructed running frequency from indoor unit to compressor at cool, dry & heating operation.
Position of LED |
|
|
|
|
|
|
|
|
Cool, Dry | 0 | Hz | 35 | 35 | Hz | 59 | Hz | 59 |
Instructed Hz No |
|
|
|
|
|
|
|
|
Heat | 0 | Hz | 44 | 40 | Hz | 63 | Hz | 63 |
Instructed Hz No |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1.When the switch is pressed between 0 to 5 seconds, Auto Mode operation starts to function.
2.When the switch is pressed between 5 to 8 seconds, the unit is forced to operate in Cooling Mode.
3.When the switch is pressed between 8 to 11 seconds, the unit is forced to operate in Heating Mode.
4.When the switch is pressed between 11 to 16 seconds and together with the signal from remote control, the unit can be changed to different controlling setting (4 type of transmission codes).
5.When the switch is pressed between 16 to 21 seconds, either “H14” error detection selection mode or the remote control signal receiving sound can be cancelled or turned on.
29