Error Codes Table

Diagnosis

Abnormality / Protection control

Abnormality

Emergency

Primary location to verify

display

 

Judgement

operation

 

 

 

 

 

 

H11

Indoor / outdoor abnormal

> 1 min after starting

Indoor fan operation

Internal / external cable connections

 

communication

operation

only

Indoor / Outdoor PCB

 

 

 

 

H14

Indoor intake air temperature sensor

Continue for 5 sec.

Intake air temperature sensor

 

abnormality

 

 

(defective or disconnected)

H15

Outdoor compressor temperature sensor

Continue for 5 sec.

Compressor temperature sensor

 

abnormality

 

 

(defective or disconnected)

H16

Outdoor Current Transformer open

Outdoor PCB

 

circuit

 

 

IPM (Power transistor) module

 

 

 

 

H19

Indoor fan motor merchanism lock

Indoor PCB

 

 

 

 

Fan motor

H23

Indoor heat exchanger temperature

Continue for 5 sec.

O

Heat exchanger temperature sensor

 

sensor abnormality

 

(Cooling only)

(defective or disconnected)

H26

Ion abnormality

Indoor PCB

 

 

 

 

Ionizer

H27

Outdoor air temperature sensor

Continue for 5 sec.

O

Outdoor temperature sensor

 

abnormality

 

 

(defective or disconnected)

H28

Outdoor heat exchanger temperature

Continue for 5 sec.

O

Outdoor heat exchanger

 

sensor abnormality

 

 

temperature sensor (defective or

 

 

 

 

disconnected)

H30

Discharge temperature sensor

Continue for 5 sec.

Discharge temperature sensor

 

abnormality

 

 

 

H33

Indoor/Outdoor wrong connection

Indoor/Outdoor supply voltage

H97

Outdoor Fan Motor lock abnormality

Outdoor PCB

 

 

 

 

Outdoor Fan Motor

H98

Indoor high pressure protection

Air filter dirty

 

 

 

 

Air circulation short circuit

H99

Indoor heat exchanger anti-freezing

Insufficient refrigerant

 

protection

 

 

Air filter dirty

 

 

 

 

F11

Cooling / Heating cycle changeover

4 times occurance

4-way valve

 

abnormality

within 30 minutes

 

V-coil

 

 

 

 

F90

PFC control

4 times occurance

Voltage at PFC

 

 

within 10 minutes

 

 

F91

Refrigeration cycle abnormality

7 times occurance

No refrigerant

 

 

continuously

 

(3-way valve is closed)

 

 

 

 

 

 

 

 

 

F93

Outdoor compressor abnormal revolution

4 times occurance

Outdoor compressor

 

 

within 20 minutes

 

 

F95

Cool high pressure protection

4 times occurance

Outdoor refrigerant circuit

 

 

within 20 minutes

 

 

F96

IPM (power transistor) overheating

Excess refrigerant

 

protection

 

 

Improper heat radiation

 

 

 

 

 

 

 

 

IPM (Power transistor)

F97

Outdoor compressor overheating

4 times occurance

Insufficient refrigerant

 

protection

within 20 minutes

 

Compressor

 

 

 

 

F98

Total running current protection

3 times occurance

Excess refrigerant

 

 

within 20 minutes

 

Improper heat radiation

 

 

 

 

F99

Outdoor Direct Current (DC) peak

7 times occurance

Outdoor PCB

 

detection

continuously

 

IPM (Power transistor)

 

 

 

 

 

 

 

 

Compressor

Note:

“O” - Frequency measured and fan speed fixed.

The memory data of error code is erased when the power supply is cut off, or press the Auto Switch until “beep” sound heard following by pressing the “RESET” button at Remote Control.

Although operation forced to stop when abnormality detected, emergency operation is possible for certain errors (refer to Error Codes Table) by using Remote Control or Auto Switch at indoor unit. However, the Remote Control signal receiving sound is changed from one “beep” to four “beep” sounds.