1.Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1 below. When the air conditioner is stopped using remote control, the vane will shift to close position.

2.Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the vane will shift to close position.

Horizontal Airflow

1.Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the angles as stated below. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1 below.

Operation Mode

 

Vane Angle (°)

Heating, with heat exchanger temperature

A

55 ~ 125

 

 

 

 

B

90

Cooling, Soft Dry and Fan, Ion

 

55 ~ 125

 

 

 

2.Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below and the positions of the vane are as Figure 2 above.

Pattern

1

2

3

4

5

Airflow Direction

 

 

 

 

 

Patterns at Remote

 

 

 

 

 

Control

 

 

 

 

 

 

 

 

 

 

 

Vane Angle (°)

90

55

70

110

125

 

 

 

 

 

 

25