Panasonic EYFLA2A, EYFLA2Q Tightening Torque Chart for Reference Use, Using the Interval Set, N m

Models: EYFLA2Q

1 48
Download 48 pages 53.09 Kb
Page 11
Image 11
Tightening Torque Chart (for Reference Use)

You can select from 30 torque clutch settings (1 to 30).

Use figures from the Tightening Torque Chart to guide your selection of torque clutch setting. (See the following tighten- ing torque chart)

2.Press the OK button to accept the select- ed torque clutch setting.

The control panel will stop flashing and light up.

CAUTION:

You must press the OK button in order for the selected setting to take effect.

Be sure to verify the new value after changing the setting. (See page 11.)

Tightening Torque Chart (for Reference Use)

The values illustrated on this chart were mea- sured under the conditions described below and are provided for reference purposes. Actual tightening torque varies with ambient conditions (the particular bolt being tightened, hardware being used, method of holding the bolt in place, etc.).

N • m

 

 

 

 

 

60

 

 

 

 

 

 

50

 

 

 

 

 

EYFLA3 (M10)

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

EYFLA2 (M8)

30

 

 

 

 

EYFLA3 (M8)

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

EYFLA1 (M8)

10

 

 

 

 

 

EYFLA2 (M6)

 

 

 

 

 

 

 

 

 

 

 

 

EYFLA1 (M6)

0

 

 

 

 

 

 

1

2 3

4 5

6

7

8

9 10 111213 1415 16171819202122232425 26272829 30

Measurement conditions

• Temperature: Room temperature (20°C/68°F)

Using the Interval Set

The interval set operates to prevent the tool from operating after it automatically stops as a result of the torque control function, even if the switch is engaged.

1.Set the tool to configuration mode. (See page 10.)

2.Press the interval set button.

The control panel will begin flashing.

Display: The number 0 flashes on and off.

Battery indication lamp: The middle bar of the battery flashes on and off.

Display

Battery indication lamp

3.

Press the

and

buttons to set the

 

desired time.

 

 

 

 

Buttons

Display

Seconds

 

 

30

 

3

 

 

1

 

0.1

 

 

0

 

Off

4. Press the OK button to accept the select-

 

ed setting.

 

 

 

 

• The control panel will stop flashing and

 

light up, and the torque clutch setting

 

will be displayed.

 

 

CAUTION:

Be sure to verify the new value after changing the setting.

Initializing All Settings

Factory settings

Torque clutch setting: “F” (torque con- trol function off)

Interval setting: 0 (off)

This section explains how to revert all tool settings to their default values at the time of shipment from the factory.

The error display will be turned off.

1.Set the tool to configuration mode. (See page 10.)

2.Press the format button.

The control panel will begin flashing.

Display: The letter “F” flashes on and off.

Battery indication lamp: The upper and lower bars of the battery flash on and off.

Display

Battery indication lamp

- 11 -

Page 11
Image 11
Panasonic EYFLA2A Tightening Torque Chart for Reference Use, Using the Interval Set, Initializing All Settings, N m