PRECAUTIONS FOR PROPER USE
Amplifier
Threshold value fine adjustment
Step | Description | Display |
Press MODE key to light up |
| |
MODE indicator / ADJ (yellow). |
| |
1 |
|
|
In case the threshold value is to be increased | ||
(sensitivity to be reduced), turn the jog | ||
switch to the ‘’ side to increase the | ||
threshold value slowly. |
| |
If the jog switch is turned continuously | ||
to the ‘’ side, the threshold value | ||
2 increases rapidly. | or | |
In case the threshold value is to be | ||
decreased | (sensitivity to | be |
increased), turn the jog switch to the | ||
‘ ’ side to decrease the threshold | ||
value slowly. If the jog switch is turned continuously to | ||
the ‘’ side, the threshold value decreases rapidly. |
When jog switch is pressed, the threshold value is confirmed.
2
Output operation setting
Step | Description | Display |
| Press MODE key to light up |
|
| MODE indicator / L/D ON |
|
1 (yellow). | Displays | |
|
| |
|
| present setting |
| If the jog switch is turn to the | Light state |
| ‘’ or ‘’ direction, the output |
|
2 | operation setting will change. |
|
|
| |
|
| Dark state |
| When jog switch is pressed, |
|
| the threshold value is confirmed. |
|
3 |
| Displays |
|
| |
|
| selected setting |
Timer operation setting
•The setting for whether the timer is used or not can be done when MODE indicator / TIMER (yellow) lights up.
•10 ms
•Further, an
Key-lock function
•With the
To cancel the lock function, press both the keys for more than 3 sec. once again.
Wiring
•Make sure that the power supply is off while wiring.
•Verify that the supply voltage variation is within the rating.
•Take care that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the sensor may get burnt or damaged.
•If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
•In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground.
•Take care that
•Do not run the wires together with
•Ensure that an isolation transformer is utilized for the DC power supply. If an auto transformer is utilized, the main amplifier or power supply may be damaged.
•Make sure to use the optional
Others
•Do not use during the initial transient time (0.5 sec. approx.) after the power supply is switched on.
•Take care that the sensor is not directly exposed to fluorescent light from a
•This sensor is suitable for indoor use only.
•Avoid dust, dirt, and steam.
•Take care that the product does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc.
•This sensor cannot be used in an environment containing inflammable or explosive gasses.
•Never disassemble or modify the sensor.
(Note)
Note: The
Refer to the ‘Fiber Sensor Guide Book’ or ‘SUNX fiber sensor home page’ (http://www