Cleaning the Unit

¥Re-attachment of the sensor roller

When the sensor roller is removed while cleaning the inside of the scanner, re-attach it as shown below.

Lower sensor roller:

Attach the roller by placing the gear side to the left side of the scanner and inserting both side’s bearings into the guide grooves.

After attaching, press down on top of the sensor roller with your finger to confirm if it moves or not.

Upper sensor roller:

1Attach the roller by inserting the bearing of the gear side of the roller into the guide groove on the left side of the scanner.

Match the flat side of the bearing with the flat side of the guide groove.

2Hold the shaft on the right side of the sensor roller, push the tip of the gear, and slide the sensor roller in the direction of the arrow Œ.

Then attach the roller by inserting the bearing of the non-gear side of the roller into the guide groove on the right side of the scanner.

Match the flat side of the bearing with the flat side of the guide groove.

GearBearing

Sensor roller

Guide groove

Please attach the right side bearing in the same way.

Sensor roller 2

Bearing

1

Guide groove

Gear

￿Roller cleaning paper

Open the bag on the dotted line and take out the roller cleaning paper.

If the bag is left open for a long period of time, the alcohol will evaporate.

Please use the roller cleaning paper immediately after opening the bag.

Dotted line

§The roller cleaning paper (Model No. KV-SS03) is available from the dealer where you purchased your scanner.

For supplies and accessories: Call 1-800-346-4768 (U. S. A. only) or your dealer.

40