9. Programmable Features
65
Setting the font number in
PCL
{#}{7}{6}{9}
(KX-MB3020 only)
To set the font number to be used in PCL printing. The unit assigns a number
to each font.
1. {Menu} i {#}{7}{6}{9} i {Set}
2. Enter the font number from “000” to “054”, using the dial keypad.
LThe default setting is “000”.
3. {Set} i {Menu}
Note:
LIf the font source in PCL (feature #768 on page 64) is set to “DOWNLOAD
FONT”, the default setting is “001”.
LTo print the font list, see page 98.
Setting the font pitch/point in
PCL
{#}{7}{7}{0}
(KX-MB3020 only)
To set the font pitch/point to be used in PCL printing.
1. {Menu} i {#}{7}{7}{0} i {Set}
2. Enter the font pitch from “00.44” to “99.99”, or the point from “004.00”
to “999.75”, using the dial keypad.
LThe default pitch is “10.00” and the default point is “012.00”.
LThe setting will be either font pitch or point depending on the font
number selected in feature #769 (page 65).
3. {Set} i {Menu}
Setting the symbol set in PCL
{#}{7}{7}{1}
(KX-MB3020 only)
To set the symbol set to be used in PCL printing.
1. {Menu} i {#}{7}{7}{1}
2. Press {V} or {^} repeatedly to display the desired symbol set. i {Set}
i {Menu}
Setting the line breaks in PCL
{#}{7}{7}{2}
(KX-MB3020 only)
To set each behavior when receiving CR, LF, and FF codes.
{1} “CR/LF/FF” (default): CR=CR, LF=LF, FF=FF
{2} “CR+LF/LF/FF”: CR=CR+LF, LF=LF, FF=FF
{3} “CR/CR+LF/CR+FF”: CR=CR, LF=CR+LF, FF=CR+FF
Setting the waiting time for
auto continue mode
{#}{7}{7}{3}
(KX-MB3020 only)
To set the length of time before the unit recovers if a memory overflow occurs.
{1} “OFF” (default): Deactivates this feature.
{2} “20s”: 20 seconds
{3} “30s”: 30 seconds
{4} “60s”: 60 seconds
{5} “90s”: 90 seconds
{6} “120s”: 120 seconds
Changing the data timeout
setting
{#}{7}{7}{4}
The unit will automatically print the remaining data in memory when the
computer does not send data to the unit during the set time.
1. {Menu} i {#}{7}{7}{4} i {Set}
2. Enter the desired data timeout setting from “005” seconds to “600”
seconds, using the dial keypad.
LThe default setting is “060” seconds.
3. {Set} i {Menu}
Setting mutual A4/letter print
{#}{7}{7}{6}
This feature allows printing in A4-size even if letter-size recording paper is
loaded, and vice versa.
{0} “OFF”: Deactivates this feature.
{1} “ON” (default): Printing is possible between A4/letter-size.
Feature/Code Selection