:.......................until the desired CO number (01 through
12)
appears.
_....................................... until the desired time appears
1.5sec _e_;< _
2.5 set
3.5 set . . . . . . . . . . . . . . . . . . . .
: default (all 12 &Os)
4.5 set
: to assign the same on all 12 COs
Description
The KX-T123211 may require a pause time to
access Central Office Line or computer accessed
line.
The pause time may be changed to 1.5sec,
2.5sec, 3.5sec or4.5sec.
Programming
1.
Dial (53).
Pause Time will be displayed.
2. Press the NEXT button.
CO NO ? + will be displayed.
3. Press the NEXT button or dial the CO number
(01 through 12).
CO 01 : 3.5secwill be displayed and 3.5sec
will blink.
4. Repeat pressing the SELECT button until the
desired time (1.5sec, 2.5sec, 3.5sec 4.5sec) is
displayed.
5. Press the MEMORY button.
The LCD will stop blinking.
6. e To advance to the next CO number,
press the NEXT button.
l
To return to the previous CO number,
press the PREV button
l
To go to the desired CO number,
press the SELECT button and then dial the
CO number.
7. Repeat steps 4 to 6, to program the
assignment of the other CO numbers.
8. To return to the initial program mode, press
the END button.
Programming Table
i
See page 7-23.