Panasonic KX-T206E Outgoing Permitted CO2 Assignment Day/Night, CO1 Ringing Assignment Day/Night

Models: KX-T206E

1 40
Download 40 pages 49.54 Kb
Page 22
Image 22
Outgoing Permitted CO2 Assignment (Day/Night)

System Programming

Outgoing Permitted CO2 Assignment (Day/Night)

Description

Determines the extensions which can have access to CO line 2 in both day and night modes. The extension users can make outgoing CO calls if their extensions are assigned as “ENABLE”.

Input Format

0 3 (for day) / 7 3 (for night) [A] [B]

 

Explanation

[A]= 1 through 6 (corresponding to extension no. 21 through 26)

[B]= 0: DISABLE/ 1: ENABLE

Default All extensions– 1: ENABLE

CO1 Ringing Assignment (Day/Night)

Description

Assigns the extensions which will ring when a call from CO line 1 is received in both day and modes.

Input Format

0 4 (for day) / 7 4 (for night) [A] [B]

 

Explanation

[A]= 1 through 6 (corresponding to extension no. 21 through 26)

[B]= 0: DISABLE (not ring)/ 1: ENABLE (ring)

Default

extension 21–1: ENABLE other extensions– 0: DISABLE

CO2 Ringing Assignment (Day/Night)

Description

Assigns the extensions which will ring when a call from CO line 2 is received in both day and modes.

Input Format

0 5 (for day) / 7 5 (for night) [A] [B]

 

Explanation

[A]= 1 through 6 (corresponding to extension no. 21 through 26)

[B]= 0: DISABLE (not ring)/ 1: ENABLE (ring)

Default

extension 21–1: ENABLE other extensions– 0: DISABLE

22

Page 22
Image 22
Panasonic KX-T206E manual Outgoing Permitted CO2 Assignment Day/Night, CO1 Ringing Assignment Day/Night, System Programming