4-28 System Programming
[204], [206] 4.2 System Programming
Assigns the minimum length of the pause time the system waits before dialling after seizing
an exchange line.
Default 0 millisecond
Feature Reference
Section 3, Features
Outside Calling
6
0
2

[206] Dialling Start Time

NEXT
SELECT
STORE
END
(0/250/500/750/
1000/1250/1500 ms)
Assigns the start time of a conversation either immediately after an exchange line is seized
or after dialling. This corresponds to the length of the conversation displayed on the LCD
and printed on the printer (SMDR).
Default 10 seconds after dialling
If reverse signal detection is enabled in program [424] “Reverse (Polarity) Circuit
Assignment”, the system will automatically start the timer immediately after an external
party answers a call.
Feature References
Section 3, Features
Polarity Reverse Detection, Station Message Detail Recording (SMDR)
4
0
2

[204] Call Duration Count Start Time

NEXT
SELECT
STORE
END
(5/10/15/20/25/30/
35/40/45/50 sec after
dial/Instantly)
!
!