System Programming 4-45
4.2 System Programming [402]-[403]
If the system is installed behind a host PBX, each exchange line may require an access code
to make an outside call. Up to 8 access codes can be stored for each exchange line. When
the programmed codes are dialled, the pause time assigned in program [417] “Pause Time”
is automatically inserted, and call barring is applied after the code.
*1Exchange line number: 1 through 6 / (All exchange lines)
*2Insert a “, for each code using the button on the overlay.
Example:
• Access codes 81,82 on exchange line number 1
Default All exchange lines – Not stored
To correct a wrong entry, press the CLEAR button and enter the new one.
Feature Reference
Section 3, Features
Host PBX Access
,
Selects a pulse rate for each exchange line which sets “Pulse Mode” or “Call block Mode” in
program [401] “Dial Mode”. There are 2 pulse rates, Low Speed (10 pps) and High Speed
(20 pps).
*Exchange line number: 1 through 6 / (All exchange lines)
Default All exchange lines – Low Speed
0
4

[402] Pulse Speed Selection

3
0
4

[403] Host PBX Access Codes

NEXT
STORE
END
access code*2
Up to 8 access codes
1 or 2 digits
(0···9)
3
0
NEXT
STORE
END
1
8
8
1
,
2
(Low/High
Speed)
exchange line no.*1
To continue
(1
···
6/ )
(1
···
6/ )
2
NEXT
SELECT
END
exchange line no.*
NEXT
PREV
or
SELECT
To continue
To continue
STORE
NEXT
PREV
or
To continue
!
!
SELECT