Allows the extension assigned as an operator or manager to record up to 2 outgoing voice
messages (maximum 30 seconds each). This message is played when a caller accesses the
DISA or UCD feature. An optional OGM/FAX Detection Card is required to program the
OGM.
The following are some examples of OGM and flow chart.
Case 1: Receives 2 calls at a time – OGM for DISA.
(Do not want customers to be kept waiting.)
OGM1: “This is A company. For the sales division,press 1. For the service
division, press 2. To call the operator, press 0.”
OGM2: Same as OGM 1
Required Settings: [502] “MODE1”
[414]-[416] “DISA1”
Case 2: Uses the OGM in the day, night and lunch modes – OGM for DISA.
OGM1: “This is A company. For the sales division,press 1. For the service
division, press 2. To call the operator, press 0.”
OGM2: “We are sorry but our office is closed for the day.
Required Settings: [502] “MODE2”
[414]-[416] “DISA1” for OGM1, “DISA2” for OGM2
Outgoing Message (OGM)
DISA with
OGM
Outside Call
Outside Call
To the designated destination
OGM1
System
DISA with
OGM To the designated destination
OGM2
DISA with
OGM
Outside Call To the designated destination
OGM1
System
The call is disconnected by assigning
“Disconnect” for DISA2 in program
[510] “DISA No Dial Mode”.
(In the day mode)
DISA with
OGM
Outside Call OGM2
System
(In the night mode)
3-48 Features
O3 Features
PSQX1708ZA-05E.QX 99.10.15 10:31 AM Page 48