FEATURE CHART

Power Headlight Cord Length Bare Floor
120V AC(60Hz) Yes 24 Ft No
Tableau des caractéristiques
Alimentation Dispositif Longueur du Position
d’éclairage cordon plancher
120 V c.a. (60 Hz) Oui 6 m (24 pi) Non

DDiiaaggrraammaa ddee ccaarraacctteerrííssttiiccaass

VVoollttaajjeeLLuuzzEExxtteennssiióónnUUssoo ssiinn
ddee ccoorrddóónnaallffoommbbrraa
120 V c.a. (60 Hz)
Si 6 m (24pi) No
- 11 -
Air Turbine
Turbine àair
Turbina de aire
Motor Protector
Protecteur du moteur
Protector de motor
Adjustable Handle
Release Button
Bouton de dégagement
de la poignée ajustable
Botón de liberación del
mango ajustable.
Short Hose
Tuyau court
Manguera corta
Extension Hose
Tuyau dextension
Manguera expansible
Carrying Handle
Poignée de transport
Mango para transportar
Crevice Tool
Suceur plat
Herramienta
para tapices
Body Release
Pedal
Pédale de réglage
de linclinaison du boîtier
Pedal de liberación
del mango
Wand
Tube
Tubo
Power Cord
Cordon d'alimentation
Cordón electrico
Dusting Brush
Brosse àépousseter
Cepillo para sacudir
- 50 -

BEFORE REQUESTING SERVICE

Review this chart to find do-it-yourself solutions for minor performance
problems. Any service needed, other than those described in these
Operating Instructions, should be performed by an authorized service
representative.
WARNING Electrical Shock or Personal Injury Hazard
Disconnect the electrical supply before servicing or cleaning the vacuum cleaner.
Failure to do so could result in electrical shock or personal injury from vacuum
cleaner suddenly starting.
Vacuum Cleaner 1. Unplugged at wall outlet. 1. Plug in firmly, turn on vacuum cleaner.
won’t run. 2. Tripped circuit breaker/blown fuse 2. Reset circuit breaker or replace
at household service panel. fuse.
3. Thermal protector tripped. 3. Unplug vacuum cleaner, allow to cool
and thermal protector will reset itself.
1. Full or clogged dust bin. 1. Empty dust bin.
2. Worn agitator. 2. Take to your nearest Panasonic
Service Center.
3. Clogged nozzle. 3. Check for clogs.
4. Clogged hose. 4. Check for clogs.
5. Hole in hose. 5. Take to your nearest Panasonic
Service Center.
6. Hose not inserted fully 6. Check hose connection
7. Motor protection system activated. 7. Check for clogs.
8. Dirty filters. 8. Change primary filter and
exhaust filter.
Light won’t work. 1. Burned out light bulb. 1. Change light bulb.
Agitator does not turn. 1. Broken belt. 1. Replace belt.
Air flow restricted 1. Attachment use restricts air flow. 1. See ATTACHMENTS.
with attachment use.
Sound changes. 2. New carpet fuzz clogged air path. 2. See CLOG REMOVAL and clean
hose.
PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
Poor job of dirt