89
Settings
2. Input/output signal settings

2-2-1. Assigning the output signals

The output signals can be assigned to the SDI OUT1 to SDI
OUT5 connectors and DVI OUT connector.
On the Output sub menu, use [F2] to select the output
to be set using the Select item.
Refer to “2-2. Output signal settings”.
Use [F1] to display the Assign sub menu.
Use [F2] to set the type of output signal using the
Source item.
PGM An image provided with the wipe, mix, key,
downstream key or other effect is output at
the switcher’s main line output.
PVW This is the preview output that enables the
next operation to be checked before it is
executed.
AUX1 to 4 The signals selected by the 4 lines of AUX
buses (AUX1 to AUX4) are output.
CLN The clean signal (the image resulting when
the key, downstream key or other effect
has been removed from the PGM signal) is
output.
Refer to “Assigning the CLN signal”.
MV The multi view display signals are output.
Multiple input signals and output signals are
reduced in size and output to one screen.
KeyOut The key signal is output.
MEM-PVW In the memory preview mode, the shot
memory and event memory effects are output
to preview.
Use [F3] to set the output mode using the Mode item.
Normal The same signals as the system format
signals are output.
Down
Convert
(down-
converter)
This can be selected when the SDI output
board (option: AV-HS04M7) has been
connected.
When the system format is 1080/59.94i or
720/59.94p, the signals are output in the
480/59.94i format.
When the system format is 1080/50i or
720/50p, the signals are output in the 576/50i
format.
When the system format is SD (480/59.94i or
576/50i), this setting cannot be selected.
Assigning the CLN signal
Set KEYCLN or DSKCLN as the CLN output.
Press the s button to light its indicator, and display the
Config menu.
Use [F1] to display the Assign sub menu.
Use [F3] to select the type of output signal using the
CLN item.
Key The PGM signals minus the key effects are
output.
The Key, PinP1, PinP2 and DSK effects are
not added.
DSK The PGM signal minus the downstream key
effects are output.

2-2-2. Setting the SDI output color range

The color range can be set for the SDI output signal images.
The same setting applies to all the SDI output signals.
On the Output sub menu, use [F5] to set the color range
using the SDI Limit item.
Refer to “2-2. Output signal settings”.
Off The color range is not restricted.
108 The amplitude level of the colors (R, G and
B) is restricted to 0 % - 108 %.
104 The amplitude level of the colors (R, G and
B) is restricted to 0 % - 104 %.
100 The amplitude level of the colors (R, G and
B) is restricted to 0 % - 100 %.