CONNECTIONS

Precautions

The following connections should be made by qualified service personnel or system installers in accordance with all local codes.

Turn off the power at the fuse box before starting the installation work, or it so could result in fire, electric shock, personal injury, and material damage.

 

24 V AC Cable for Heater

 

Separate 2-wire

 

 

 

24 V AC Cable for camera

 

24 V AC

 

 

RS485 Data Port

Twisted Pair Cable*1

To Matrix Switcher,

(RJ-12)

etc.

Video Output

Coaxial Cable (5C-2V)*2

 

Connector

To VIDEO IN port

 

 

(BNC)

(CAMERA IN)

Alarm Input

 

 

Connector

8P Alarm Cable (provided)

 

 

 

To sensor, etc.

Alarm Output

4P Alarm Cable (provided)

 

Connector

 

 

To buzzer,

display device, etc.

*1: For twisted pair cable, use shielded low-impedance cable with a thickness of at least AWG#22 (0.33 mm2).

*2: Keep the overall length of coaxial cable under 1200 meters (in the case of 5C-2V).

*3: Be sure to connect the grounding cable to ground.

RS485 Data Port

Data

Red

Orange

Tx

Yellow

Data

Green

Rx

 

(RJ-12)

T(B)

T(A)

R(B)

R(A)

Alarm Input Connector

Alarm In 1 (Black)

GND (Brown)

Alarm In 2 (Red)

GND (Orange)

Alarm In 3 (Yellow)

GND (Light Blue or Green)

Alarm In 4 (Blue)

GND (Violet)

Alarm Output Connector

Alarm Out 1 (Grey)

GND (White)

Alarm Out 2 (Pink)

GND (Light Green

or Light Blue)

Alarm In/Out Ratings

Alarm In : 5 V DC pull-up input. Drive capacity of at lease 0.2 mA required.

OFF : 4 V DC minimum 5 V DC maximum, or open

ON : 1 V DC maximum or short

Alarm Out : Open collector output. 16 V DC, 100 mA maximum drive capacity

OFF : Open

ON : 100 mA maximum

*When connecting to an external device, set up the system so the ratings are not exceeded.

Note: Do not turn off camera power within 30 seconds after turning it on. Doing so can cause pan, tilt, zoom, or focus to go out of position.

• 24 V AC Power Supply Connection

Recommended wire gauge sizes for 24 V AC line

Copper wire size

#24

#22

#20

#18

(AWG)

 

(0.22mm2)

(0.33mm2)

(0.52mm2)

(0.83mm2)

 

 

 

 

 

 

Length

(m)

20

30

45

75

of cable

 

 

 

 

 

(ft)

65

100

160

260

(approx.)

 

 

 

 

 

 

Accessory Connector Information

Pin no.

Power source

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

24 V AC LIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

24 V AC NEUTRAL

 

4

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Ground

 

2

 

1

4

Not use

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-19-

Page 19
Image 19