8.0 Using Access Control

 

 

8.1 Entering & Exiting

LCD LED

 

 

Depending on how your system is installed and on the type of keypad, there are various

 

 

 

 

ways to enter and exit Access Control doors:

 

 

• Present your Access Control card to the reader or the

 

 

EVO641R or DGP2-641RB keypad. The system will

 

 

verify that the card is allowed access according to its

 

 

assigned Access Level and Schedule. If it is accepted,

 

 

the system will unlock the door. The reader’s light can

 

 

be programmed by the installer to turn green or

 

 

extinguish briefly to indicate that the door can be

 

 

opened.

 

 

• When the motion detector detects movement (Request

 

 

for Exit), it will unlock the door to permit passage from

 

 

inside.

 

 

• Enter your user access code on the keypad and press

[ACC].

• If the Access Control door is on a “Door Unlocked Schedule”, you may be able to open Access Control

doors without using a user access code or an Access Control card. Depending on the door’s programming, the door can remain unlocked during the entire programmed schedule or the door can unlock once a valid Access Control card is presented to the reader during the schedule and then will remain unlocked for the remainder of the schedule.

LCD EVO641R / DGP2-641RB only

LCD EVO641R / DGP2-641RB only

8.2Arming and Disarming with Card

8.2.1Arming with Card

presented to a door during its assigned Schedule (refer to step 8 in section

7.5.1on page 14).

presented to a door within its assigned Access Level (refer to step 8 in section

7.5.1on page 14).

programmed to allow arming (options [4] and [5] in section 7.7 on page 15).

assigned to all areas that are assigned to the Access Control door (refer to step 7 in section 7.5.1 on page 14), or assigned to at least one of the areas assigned to the Access Control door depending on how your installer has programmed the Access Control door.

8.2.2Disarming with Card

To disarm and unlock an Access Control door when the area assigned to it is armed, present your Access Control card to the reader or EVO641R / DGP2- 641RB keypad (door). The Access Control card must be:

presented to a door during its assigned Schedule (refer to step 8 in section

7.5.1on page 14).

presented to a door within its assigned Access Level (refer to step 8 in section

7.5.1on page 14).

programmed to allow disarming (option [2] in section 7.7 on page 15).

assigned to all areas that are assigned to the Access Control door (refer to step 7 in section 7.5.1 on page 14), or assigned to at least one of the areas assigned to the Access Control door depending on how your installer has programmed the Access Control door.

EVO Systems 17

Page 19
Image 19
Paradox Hellas S.A EVO48 manual Using Access Control, Entering & Exiting, Arming and Disarming with Card, Arming with Card