5.8 Auto-Arming

LCD LED

 

 

If enabled by your installer, you can set the time that an area will arm itself automatically.

 

 

 

 

5.8.1 Timed Auto-Arming

 

 

Your installer can set Timed Auto-Arming to function in either Force or Stay arming

 

 

mode. A sixty-second (default value) Exit Delay sequence will begin prior to your

 

 

system automatically arming itself at the programmed time.

To set the Auto-Arming timer:

1. Enter your [ACCESS CODE].

2. Press the [0] button.

3. Press the [MEM] button.

4. If you have access to more than one area, press the area’s number, or use the [S] and [T] buttons and press the [ACC] button when the area you want to program appears on the screen.

5. Enter the time you want the area to be armed according to the 24-hour clock (i.e. 9 a.m. is 09:00 and 9 p.m. is 21:00).

6. Press the [ENTER] button to save and exit.

If you are using the DGP2-648BL LED keypad, The MEM action light will flash if a time is not already programmed. The PRG action light, the area light of the chosen area, and the first number of the previous time set will illuminate (10 light = zero).

5.8.2No Movement Auto-Arming

Your system can be programmed to send a report to your monitoring station and/ or arm the system if there is no activity in the area during a specified period of time. Your installer can set No Movement Auto-Arming to function in either Regular or Stay arming mode.

EVO Systems 9

Page 11
Image 11
Paradox Hellas S.A EVO48, EVO192 manual Timed Auto-Arming, No Movement Auto-Arming