Paradox Hellas S.A EVO48, EVO192 manual Access Control User Options

Models: EVO192 EVO48

1 36
Download 36 pages 46.17 Kb
Page 17
Image 17

LCD LED

LCD

7.6User Options

Options [1] and [2]: Master Feature

When option [1] is OFF, the User cannot program other users into the system. When option [1] is ON and option [2] is OFF, the user can program and modify user access codes (P.I.N. only) and User Labels.

When both options [1] and [2] are ON, the user has Full Master rights. The user can create or modify user access codes, User Options, User Access Control Options, Access Card Numbers, User Labels and Area Assignments according to their own programming. For example, if the Full Master User has access to area #1 and option [4] (Bypass) only, the Full Master user can only assign area #1 and option [4] to other users in the system.

Option [3]: Duress

When option [3] is ON, the Duress feature is enabled. This feature is used when someone forces a user to arm or disarm an area(s). By entering a user access code (P.I.N.) reserved for the Duress feature, the system will arm or disarm the area(s), and then send a silent alarm to the monitoring station.

Option [4]: Bypass

When option [4] is ON, the Bypass feature is enabled. This feature allows the user to deactivate zones when arming the area(s).

Option [5]: Arm Only

When option [5] is ON, the Arm Only feature is enabled. The user can arm assigned areas with either a card or code, but cannot disarm. When the option is OFF, the user can either arm or disarm assigned areas.

Option [6]: Stay & Instant Arm

When option [6] is ON, the Stay and Instant arm features are enabled. The user can now Stay or Instant arm their assigned areas.

Option [7]: Force Arm

When option [7] is ON, the Force arm feature is enabled. The user can now Force arm their assigned areas.

Option [8]: Area Access

When option [8] is ON, the keypad will permit access to all the areas assigned to the user access code. When option [8] is OFF, the keypad will only permit access to the areas it controls. For example, the keypad is assigned area 1 only, and your user access code is assigned areas 1 to 8. If the option is ON, you can access all eight areas from the keypad. If the option is OFF, you can only access area 1.

By default all users can Regular arm the system.

7.7Access Control User Options

Option [1]: Access Control

When option [1] is ON, the user can gain access to an access control door when Access Control is enabled in the system. A user that is not assigned to any partition, but has the Access Control option (Option [1]) enabled, can now gain access to an access control door by entering a code # (P.I.N.) and then pressing the [ACC] keypad key. When the option is OFF, the user cannot access an Access Control door.

Option [2]: Can Disarm with Access Card

When option [2] is ON, a User’s Access Control card can unlock and disarm an armed Access Control door. When option [2] is OFF, follow the settings in option [8] on page 17.

For option [2] to function in the ON position, option [5] “Arm Only” in the User Options must be disabled (refer to section 7.6 on page 15).