4. Configuration

Configure Management Inband Address

The configure management inband address command specifies the IP address of the unit.

configure management inband address {ip_address} { subnet_mask}

Minimum Access Level: Administrator

ip_address – Specifies the management IP address. Default is 0.0.0.0 (disabled). Do not configure inband and out-of-band management on the same subnet.

subnet_mask – Specifies the subnet mask to be applied to the IP address. The default mask is 255.255.255.0.

Example:

PDYN# configure management inband address 137.90.127.3 255.255.255.0

Configure Management Out-of-Band Address

The configure management out-of-band address command specifies the IP address of the unit that will accept management traffic on the out-of-band management port.

configure management out-of-band address {bootp {{ip_address} { subnet_mask} }

Minimum Access Level: Administrator

bootp – Specifies that a BOOTP server will determine the management IP address. ip_address – Specifies the management IP address. The default address is

10.10.10.10.Do not configure inband and out-of-band management on the same

subnet.

subnet_mask – Specifies the subnet mask to be applied to the IP address. The default mask is 255.255.255.0.

Example:

PDYN# configure management out-of-band address bootp

PDYN# configure management out-of-band address 137.90.127.3 255.255.255.0

2600-A2-GN20-40

March 2005

4-3

Page 39
Image 39
Paradyne BitStorm 2600 manual Configure Management Inband Address