Paradyne Hotwire 5446 installation instructions Troubleshooting, LED Symptom Action

Models: Hotwire 5446

1 23
Download 23 pages 19.41 Kb
Page 14
Image 14

Troubleshooting

LED Symptom

Action

 

 

All LEDs are on.

If the LEDs remain on after ten minutes, the RTU is not

 

functional. Contact the NSP.

 

 

ALM LED remains

The power-on self-test may have failed. Unplug the unit and

on.

reapply power. If the alarm light is still on, contact the NSP.

 

 

ALM and TST

Firmware download may be in progress. If firmware download

LEDs are blinking.

is not in progress or the LEDs remain on after ten minutes,

 

contact the NSP.

 

 

DSL LED is off.

Verify that the DSL cable is securely installed on both ends.

 

If the problem continues, contact the NSP.

 

 

DSL LED continues

The RTU is attempting to establish the DSL link or adjusting the

to blink after the

rate of the DSL line due to line conditions. If the DSL LED

power-on self-test.

continues to blink for more than ten minutes, contact the NSP.

 

 

DSL LED is on and

The DSL link has been established but there is no data

there is no data

transmission. Verify the Ethernet connection. If the problem

transmission.

persists, contact the NSP.

 

 

DSL and Ethernet

Verify that your IP address, subnet mask, and default gateway

LEDs are on and

have been entered correctly in the end-user system.

there is no data

 

From the end-user system, use the PC PING utility to ping the

transmission.

5446 RTU's IP address.

 

 

 

 

If no response to the ping, use the PC ARP (Address

 

Resolution Protocol) utility to verify the IP address and physical

 

address (MAC address) from the end-user system to the 5446

 

RTU. If the problem continues, contact the NSP.

 

 

Ethernet LED is off.

Verify that the Ethernet 10BaseT cable is securely installed at

 

both ends, and at least one PC is connected and powered on.

 

 

 

Verify that the correct straight-through or crossover cable is

 

installed. Refer to Installing the Hotwire 5446 RTU, page 8.

 

 

PWR LED is off.

Check that the power cord is securely installed on both ends.

 

 

 

If no LEDs are on, the power supply may be defective. Test the

 

outlet to verify power. If the problem persists, contact the NSP.

 

 

 

If other LEDs are on, the PWR LED may be burned out. Unplug

 

the unit and reapply power; watch all the LEDs during the

 

power-on self-test to verify that the PWR LED is functioning.

 

 

TST LED is on.

A test initiated by the NSP may be active. Wait five minutes. If

 

the TST LED does not go off, contact the NSP.

 

 

14

Page 14
Image 14
Paradyne Hotwire 5446 installation instructions Troubleshooting, LED Symptom Action