If the wiring is extended or a completely new cable fitted a

 

3-pin 13 amp plug should be fitted. (See Fig.4a). Connect the

GREEN AND

wires as follows:

 

YELLOW

BROWN to the Live Terminal.

 

BLUE to the Neutral Terminal.

 

GREEN and YELLOW to the Earth Terminal.

 

As the colours of the wires in the mains lead which you fit may

 

not correspond with the coloured markings identifying the

 

terminals in your plug, proceed as follows:

 

The wire which is GREEN and YELLOW must be connected

 

to the terminal in the plug which is marked with the letter 'E' or

 

by the earth symbol

or coloured GREEN or GREEN and

 

YELLOW.

The wire which is coloured BLUE must be connected to the

BLUE

 

terminal which is marked with the letter 'N' or coloured BLACK.

 

The wire which is coloured BROWN must be connected to the

 

terminal which is marked with the letter 'L' or coloured RED.

 

FIT A 3 AMP FUSE TO THE PLUG HOLDER.

 

Ensure that the supply cable cannot get caught by the stability bracket. Plug in the appliance.

6. PRESSURE TESTING

Fig.4a

3 AMP

BROWN

1The oven injector is used as a pressure test point.

Remove the oven furniture. Remove oven burner box retaining clips (one spring clip from each side) and remove box front cover. Replace one clip back into the right hand side of the burner box.

Remove oven burner by removing the spring clip from the right hand side of the oven burner and slide burner off injector whilst easing it forward and taking care not to strain the F.S.D. phial.

2.Connect the pressure gauge to the oven injector.

3.Check the supply pressure by turning the thermostat on and one hotplate tap full on and light the

appropriate burner. The pressure should be either:-

(i) For Natural Gas

20mbar

(ii)For LP.GasThe pressure must be set to 28 mbar for use on butane or 37 mbar for use on propane.

4.Turn off the taps, disconnect the pressure gauge and replace oven burner and cover, ensuring that the F.S.D. phial is correctly located into the bracket on the burner.

5.Check operation of oven.

7. CHECKING THE GRILL

Place the grill pan containing the trivet into the grill compartment. Light the grill burner by turning the grill tap to its full on position and pushing the ignition button. As soon as the burner is lit the button can be released.

8. CHECKING THE HOTPLATE

Lift the lid. Fit the burner crowns and caps ensuring that they are correctly seated. Fit the pan supports. Check each of the hotplate burners in turn by turning the hotplate tap to it's full on position and pushing the

ignition button. As soon as the burners are lit the button can be released.

9. CHECKING LID SHUT-OFF DEVICE

1.Lift the lid.

2.Turn one hotplate burner tap to its full on position and push the ignition button.

3.Close lid. There should now be no gas supply to the hotplate and the burner will go out.

4.Turn off the hotplate tap and lift the lid. The gas supply should now be restored to the hotplate. When the tap is turned on.

46

Page 46
Image 46
Parkinson Cowan 60 GLXA Pressure Testing, Checking the Grill, Checking the Hotplate, Checking LID SHUT-OFF Device