![Switch S1-4: Must be set to the ON position (Reserved).](/images/new-backgrounds/117683/11768321x1.webp)
Switch S1-4: Must be set to the ON position (Reserved).
| Setting |
|
|
On | Reserved |
Switch S1-5: Asynchronous/Sync Operation
Use switch
| Setting |
|
|
Off | Async/Sync |
Switches S1-6 and S1-7: System Clock Mode
Use Switches
|
| Clock Mode | Description |
|
|
|
|
On | On | Internal | System clock generated internally |
Off | On | External (DTE) | System clock derived from termi- |
|
|
| nal interface |
|
|
|
|
On | Off | Receive Recover | System clock derived from the |
|
|
| received line signal |
|
|
|
|
Off | Off | Hardware Reset |
|
|
|
|
|
A pair of Model 1082s communicate synchronously across the twisted pair line connection. Therefore, you must set these switches whether your application is async or sync. For X.21 or Async applications, configure one Model 1082 for internal clock mode and the other Model 1082 for receive recover clock mode.
Important
Switch S1-8: Response to RDL Request
Use Switch
11