Pelco C2622M manual RJ-45 10BASE-T/100BASE-TX Port Status LED - Right Duplex/Collision, Meaning

Models: C2622M

1 28
Download 28 pages 52.63 Kb
Page 21
Image 21

Table C. Troubleshooting with Rear-Panel Indicators (Continued)

Indicator Color

Meaning

Possible Cause

 

Corrective Action

 

 

 

 

RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision)

 

 

 

 

Amber

Port is set to

If 10BASE-T full-duplex

 

10BASE-T full-

 

operation is desired, no action

 

duplex mode.

 

is required. If 10BASE-T full-

 

 

 

duplex operation is not

 

 

 

desired, refer to Setting

 

 

 

10BASE-T/100BASE-TX Port

 

 

 

Modes of Operation on

 

 

 

page 10 for information.

 

 

 

 

Flashing amber

Port is set to

Normal or excessive

If a normal collision occurs, no

 

10BASE-T half-

collisions occur on a half-

action is required.

 

duplex mode and

duplex link.*

If a problem with the network

 

network collision

 

exists due to excessive

 

has occurred.*

 

collisions, do any of the

 

 

 

following as appropriate:

 

 

 

If half-duplex mode is not

 

 

 

required, set the TX Mode

 

 

 

switch to full-duplex mode

 

 

 

by means of auto

 

 

 

negotiation or by forcing

 

 

 

the mode (refer to Setting

 

 

 

10BASE-T/100BASE-TX

 

 

 

Port Modes of Operation

 

 

 

on page 10 for

 

 

 

information).

 

 

 

If half-duplex mode is

 

 

 

required, do any of the

 

 

 

following as applicable:

 

 

 

Replace network cable

 

 

 

 

if it is defective or if it is

 

 

 

 

not the proper cable

 

 

 

 

type. Use Cat5e or

 

 

 

 

higher cable.

 

 

 

Ensure that cable is

 

 

 

 

proper length. Cable

 

 

 

 

length must not exceed

 

 

 

 

328 feet (100 meters).

 

 

 

Replace the network

 

 

 

 

interface card (NIC) if it

 

 

 

 

is defective or if it is

 

 

 

 

imcompatible.

 

 

 

Segment the network.

 

 

 

 

(Continued on next page)

C2622M (2/07)

21

Page 21
Image 21
Pelco C2622M manual RJ-45 10BASE-T/100BASE-TX Port Status LED - Right Duplex/Collision, Meaning, Possible Cause