Wiring And Powering Up S-PCON-U

Chapter 3: S-PCON-U (Power Connector)

Wiring And Powering Up S-PCON-U

When the S-PCON-U is connected to a PoE enabled switch, electronics inside the S-PCON-U signal the PoE switch to place power onto the input ethernet cable. This power is then directed by the S-PCON-U onto the output RJ45 Ethernet connector. When the S-PCON-U is connected to a non-PoE enabled switch it is necessary to provide an external power supply to the S-PCON-U. This DC power is then directed onto the output RJ45 Ethernet connector. If both a PoE enabled switch and DC power are connected to the S-PCON-U, priority is given to the DC power supply.

Important: The S-PCON-U device and its Power Supply must be installed within the protected area (locked area) of the access facility to meet UL requirements.

S-PCON-U Wiring and Powering up DiagramManual backgroundManual background @Manual backgroundManual background

22.9-24VDC@1A

Manual backgroundManual backgroundManual background @Manual backgroundManual backgroundManual background

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

S-PCON-U Wiring and Powering up Diagram

The output LED on the S-PCON-U provides visual feedback that the device is functioning. The LED can be illuminated green to indicate output voltage is greater than 24 VDC, amber to indicate that output voltage is between 22 and 24 VDC, or red to indicate that output voltage is below 22 VDC.

Warning: When the S-PCON-U is operating DO NOT CONNECT any ethernet device other than an S-EIDC-U to the output RJ45 connector. Damage to electronics inside the connected ethernet device could result.

Important: It is important to maintain correct polarity when connecting a DC supply to S-PCON-U. Check for proper connection of the DC supply on the provided plug prior to connecting the supply to the S-PCON-U.